© 2021 Genesis Attachments, LLC
Genesis GRX
20
Case Drain Line
All GRX Demolition Tools require a case drain line be installed, ½” line size minimum. The
pressure in this line must be below 50 PSI at all times.
Foot Switch Installation
Install the foot switch in the excavator and connect with electrical harness. Consult excavator
dealer when using an alternate to the Genesis supplied foot switch.
White Normal Open
Black Normal Open
Red
2 Amp Fuse
24 Volt
To Rotator
(A) Black (B) Green (C) White
Green To Ground
ROTATOR INSTALLATION