N o s e A s s e m b l i e s
11
N o s e T i p s
40
11
35
41
39
•
Fit Jaw Spreader Housing
9*
(71210-02101) together with ‘O’ Ring
10*
or
11*
(Jaw Spreader Housing
9*
and ‘O’ Ring
10*
or
11*
are supplied with Type 2 Nose Assembly)
•
The Jaw Spreader Housing
9*
must be tightened onto Head Piston
35
trapping Vacuum Sleeve
41
finally tighten
Locknut
39
against Jaw Spreader Housing
9*
.
For other items refer to the general assembly drawing and parts list on pages 26 and 27.
To fit Nose Tip Type 2 or Nose Extension, the Male ‘T’ Adaptor
40
must be replaced with Jaw Spreader Housing
9*
.
•
Loosen Locknut
39
using 16mm AF Spanner.
•
Unscrew and remove Male ‘T’ Adaptor
40
together with ‘O’ Ring
11
.
Items
9*
and
10*
or
11*
refer to illustrations on pages 9, 10 and 12.
9*
10* or 11*
35
41
Jaw Spreader Housing