English
5" Random Orbital Sander
Operator’s Manual GROS2304
Guidelines for Using Extension Cords
• If you are using an extension cord outdoors, be sure it is marked with the suffix “W-A” (“W” in
Canada) to indicate that it is acceptable for outdoor use.
• Be sure your extension cord is properly wired and in good electrical condition. Always replace a
damaged extension cord or have it repaired by a qualified person before using it.
• Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
SPECIFIC SAFETY RULES FOR RANDOM ORBITAL
SANDERS
WARNING:
DO NOT LET COMFORT OR FAMILIARITY WITH PRODUCT
(GAINED FROM REPEATED USE) REPLACE STRICT ADHERENCE TO
PRODUCT SAFETY RULES. If you use this tool unsafely or incorrectly, you can
suffer serious personal injury!
• Always hold the tool firmly in your hands before switching the tool
“ON”.
The reaction to the torque of the motor as it accelerates to full speed may cause the tool
to twist.
• Do not leave the tool running.
Operate the tool only when hand-held.
• This tool has not been waterproofed,
so do not use water on the workpiece
surfaces.
• Ventilate your work area adequately
when you perform sanding operations.
• Wear eye and hearing protection.
Always use safety glasses with side shields.
Unless otherwise specified, everyday glasses provide only limited impact resistance, they are not
safety glasses. Use only certified safety equipment; eye protection equipment should comply with
ANSI z87.1 standards. Protective hearing equipment should comply with ANSI s3.19 standards.
• Protect your lungs.
Wear a face or dust mask if the operation is dusty. Following this rule
will reduce the risk of personal injury.
SAFETY RULES FOR PAINT REMOVAL
WARNING:
Extreme care should be taken when removing paint. The
peelings, residue, and vapors of paint may contain lead, which is poisonous.
Exposure to even low levels of lead can cause irreversible brain and nervous
system damage. Young and unborn children are particularly vulnerable.
Before beginning any paint removal process you should determine whether the paint you are removing
contains lead. This can be done by your local health department or by a professional who uses a paint
analyzer to check for lead.
Recommended Minimum Wire Gauge for Extension Cords (120 Volt)
Nameplate
Amperes
(At Full Load)
Extension Cord Length
25 Feet
50 Feet
75 Feet
100 Feet
150 Feet
200 Feet
0–2.0
18
18
18
18
16
16
2.1–3.4
18
18
18
16
14
14
3.5–5.0
18
18
16
14
12
12
5.1–7.0
18
16
14
12
12
10
7.1–12.0
18
14
12
10
8
8
12.1–16.0
14
12
10
10
8
6
16.1–20.0
12
10
8
8
6
6