DEX/DDCMP report. When set to numeric it will read 3.
4.
Data Reset Mode: This field can be set to either AUTO or SAVE from within
the sub-menu. When set to AUTO, all resettable data will be reset after a
successful read.
5.
Event Reset Mode: This field can be set to either AUTO or SAVE from within
the sub-menu. When set to AUTO, all event data will be reset after a successful
read.
6.
Printer Baud Rate: This allows the engineer to set the correct baud rate for a
serial printer if one is to be used. It is important for this to be set correctly to
ensure successful data transfer.
6. Serial Flash: This menu only becomes available when a serial flash card is inserted
into plug J9A on the control board. It allows the engineer to upgrade the machine
software or backup data. The following operations are supported:
●
View data information
●
Delete data
●
Load data into the machine
●
Save data back from the machine
The view, delete and load options will only become available when data is held on the
card. Also, when backup data is added, a description can be entered to aid retrieval.
The following types of data are supported:
●
Firmware - The operating system and default factory machine set-up data
●
Default Data - The default factory machine set-up data - eg canister and button
layout, default run times etc.
●
Configuration Data - Any machine set-up data that can be changed by the user
●
Configuration and Sales Data - All sales data plus the set-up data that can be
changed by the operator
●
Language Data - Not currently used
The serial flash card can hold the following amounts of data - 1 copy of the firmware,
OR 4 copies of default data, and 16 copies of configuration data, and 16 copies of
configuration and sales data. The following example describes how the engineer can
download Configuration Data to the serial flash card.
IMPORTANT: Before inserting the serial flash card, ensure machine is disconnected
from the power supply.
1.
Open the door of the machine. Release the catch and open the monetary door.
Remove the control board cover and insert the serial flash card into plug J9A.
45
Technical Manual
Summary of Contents for Espresso B2C
Page 2: ......
Page 98: ...Exterior View 96 Technical Manual 2 4 5 7 8 6 10 9 11 15 14 3 12 13 1 ...
Page 100: ...Door Interior 98 Technical Manual 1 2 3 4 5 6 2 7 8 9 10 11 12 13 14 16 15 17 18 ...
Page 102: ...Console Assembly 100 Technical Manual 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...
Page 104: ...Interior View 102 Technical Manual 1 2 3 5 4 6 7 15 11 12 13 8 9 10 14 16 ...
Page 110: ...Ingredient Canister Assembly 108 Technical Manual 1 11 8 4 9 10 7 6 3 2 4 5 ...
Page 112: ...Freshbrew Canister Assembly 110 Technical Manual 6 1 4 7 8 9 3 2 4 5 ...
Page 114: ...Dispense Head Assembly 112 Technical Manual 1 2 3 4 5 6 7 8 9 10 ...
Page 116: ...Mixing System 114 Technical Manual 1 2 3 4 5 6 7 8 9 ...
Page 118: ...Power Supply Assembly 116 Technical Manual 1 2 3 4 5 7 7 7 6 ...
Page 120: ...CoEx Brewer Motor Assembly 118 Technical Manual 2 4 1 3 5 7 6 8 9 ...
Page 122: ...Water Inlet Pressure Valve Assembly 120 Technical Manual 3 2 1 4 5 ...
Page 124: ...Pressure Boiler Assembly 122 Technical Manual 2 6 3 4 1 7 5 6 ...
Page 126: ...Fresh Beans Container 124 Technical Manual 1 2 4 3 ...
Page 129: ......
Page 130: ...12955 Enterprise Way Bridgeton Missouri 63044 1200 314 298 3500 Website www cranems com ...