GENESIS MOVE LED-MS20 R User Manual Download Page 7

 

12- 

4.  Try to use another DMX controller.     

5.  Check if the DMX cables run near or run alongside to high voltage cables that may 

cause damage or interference to DMX interface circuit.   

C. Some units don’t respond to the easy controller   

1.  You may have a break in the DMX cabling. Check the LED for the response of the 

master/ slave mode signal. 

2.  Wrong DMX address in the unit. Set the proper address. 

D. No response to the sound 

1.  Make sure the unit does not receive DMX signal. 

2.  Check microphone to see if it is good by tapping the microphone 

E. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.  The motor’s drive IC on the PCB might be out of condition 

 

 

  6. Fixture Cleaning   

The cleaning of internal and external optical lenses and/or mirrors must be carried out 

periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater 

accumulation of dirt on the unit’s optics. 

y

  Clean with soft cloth using normal glass cleaning fluid. 

y

  Always dry the parts carefully. 

y

  Clean the external optics at least every 20 days. Clean the internal optics at least every 

30/60 days. 

 

 

 

 

 

 

 

 

 

 

 

13-

 

 

 

 

EC Declaration of Conformity 

 

We declare that our products (lighting equipments) comply with the 

following specification and bears CE mark in accordance with the 

provision of the Electromagnetic Compatibility (EMC) Directive 

89/336/EEC. 

 

EN55014-2: 1997 A1: 2001, EN61000-4-2: 1995; EN61000-4-3: 2002; 

EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6: 1996, 

EN61000-4-11: 1994. 

Harmonized Standard 

 

EN60598-1: 2000+ALL: 2000+A12: 2002 

Safety of household and similar electrical appliances 

Part 1: General requirements 

 

 

 

 

 

 

 

 

 

 

 

Innovation, Quality, Performance 

Summary of Contents for LED-MS20 R

Page 1: ...LED MS20 R User Guide Professional Entertainment Technology 1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 How To Set The Unit 4 How To Control The Unit 5 Troubleshooting 6 Fixt...

Page 2: ...reduce the risk of electrical shock or fire do not expose the unit to rain or moisture y Do not open the unit within five minutes after switching off Please read carefully the instruction which inclu...

Page 3: ...e functions without any change press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 m...

Page 4: ...ll the unit on the floor or under ceiling Press the MENU button up to when the is blinking on the display Use the ENTER button to change to the mode display normal It will automatically store after 8...

Page 5: ...ter LED will be constantly on and sound LED will flash to the music The other units will have to set in slave mode 9 and select normal or 2 light show mode Their DMX cables plugged into the DMX input...

Page 6: ...sconnected 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX 512 system s...

Page 7: ...nses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding c...

Reviews: