GENESIS MOVE LED-MS20 R User Manual Download Page 6

 

10- 

4.4 DMX 512 Configuration   

 

 

 

 

4.5 DMX512 Connection   

 

The DMX 512 is widely used in intelligent lighting control, with a maximum of 512 channels. 

 

 

 

11-

1.  If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin 

adapter-cable. 

2.  At last unit, the DMX cable has to be terminated with a terminator. Solder a 120 ohm 

1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it 

in the DMX-output of the last unit. 

3.  Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to 

the input of the next unit. The cable can not branched or split to a `Y` cable. DMX 512 is 

a very high-speed signal. Inadequate or damaged cables, soldered joints or corroded 

connectors can easily distort the signal and shut down the system. 

4.  The DMX output and input connectors are pass-through to maintain the DMX circuit, 

when one of the units’ power is disconnected. 

5.  Each lighting unit needs to have an address set to receive the data sent by the 

controller. The address number is between 0-511 (usually 0 & 1 are equal to 1). 

6.  The end of the DMX 512 system should be terminated to reduce signal errors. 

7.  3 pin XLR connectors are more popular than 5 pin XLR. 

3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)   

 

 

 5. Troubleshooting  

 

Following are a few common problems that may occur during operation. Here are 

some suggestions for easy troubleshooting: 

 

A. The unit does not work, no light and the fan does not work 

1.  Check the connection of power and main fuse. 

2.  Measure the mains voltage on the main connector. 

3.  Check the power on LED. 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.  If the DMX LED is on and no response to the channel, check the address settings and           

DMX polarity. 

3.  If you have intermittent DMX signal problems, check the pins on connectors or on PCB 

of the unit or the previous one. 

Summary of Contents for LED-MS20 R

Page 1: ...LED MS20 R User Guide Professional Entertainment Technology 1 TABLE OF CONTENTS 1 Safety Instruction 2 Technical Specification 3 How To Set The Unit 4 How To Control The Unit 5 Troubleshooting 6 Fixt...

Page 2: ...reduce the risk of electrical shock or fire do not expose the unit to rain or moisture y Do not open the unit within five minutes after switching off Please read carefully the instruction which inclu...

Page 3: ...e functions without any change press the MENU button again Show 1 mode Fixture is placed on the floor Tilt movement angle 210 Show 2 mode Fixture is fixed under ceiling Tilt movement angle 90 Show 3 m...

Page 4: ...ll the unit on the floor or under ceiling Press the MENU button up to when the is blinking on the display Use the ENTER button to change to the mode display normal It will automatically store after 8...

Page 5: ...ter LED will be constantly on and sound LED will flash to the music The other units will have to set in slave mode 9 and select normal or 2 light show mode Their DMX cables plugged into the DMX input...

Page 6: ...sconnected 5 Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 6 The end of the DMX 512 system s...

Page 7: ...nses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding c...

Reviews: