GFI-SASD2-Rev-G.pub 

Rev. G  04/11 

ELECTRONIC AIR CLEANER 

LIMITED FIVE YEAR WARRANTY 

 

Electronic  Air  Cleaners,  if  properly  registered  by  the  return  of  the  attached  warranty  registration  to 
General Filters, Inc., are warranted to the consumer against defects in materials and workmanship for 
a  period  of  five  years  from  the  date  of  installation,  so  long  as  the  product  has  been  installed  and 
operated  in  accordance  with  all  appropriate  manuals  and  wiring  diagrams.  Replacement  or  routinely 
replaceable  parts  such  as  prefilters,  ionizing  wires  or  carbon  filters,  are  not  covered  by  this  limited 
warranty or any other warranties. Any other defective parts will be repaired without charge except for 
removal,  reinstallation  and  transportation  costs.  To  obtain  repair  service  under  this  limited  warranty, 
the consumer must send the defective part to General Filters, Inc. 
 
THERE  ARE  NOT  EXPRESS  WARRANTIES  COVERING  THIS  ELECTRONIC  AIR  CLEANER 
OTHER THAN AS SET FORTH ABOVE. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. THE MANUFACTURER 
ASSUMES  NO  LIABILITY  IN  CONNECTION  WITH  THE  INSTALLATION  OR  USE  OF  THIS 
PRODUCT,  EXCEPT  AS  STATED  IN  THE  LIMITED WARRANTY.  THE  MANUFACTURER WILL  IN 
NO EVENT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. 
 
This  limited  warranty  gives  you  specific  legal  rights,  and  you  may  also  have  other  rights  which  vary 
from  state  to  state.  Some  states  do  not  allow  either  limitations  on  implied  warranties,  or  exclusions 
from incidental or consequential damages, so the above exclusion and limitation may not apply to you. 
 
Any questions pertaining to this limited warranty should be addressed to General Filters, Inc. General 
Filters,  Inc.  has  elected  not  to  make  available  the  informal  dispute  settlement  mechanism  which  is 
specified in the Magnuson-Moss Warranty Act. 

G

 

Summary of Contents for GA50A14

Page 1: ...gi bacteria viruses and more down to 0 01 micron Light Weight Aluminum Collecting Cells are durable and easy to maintain Cell Guide ensures proper placement of collecting cells Activated Carbon Filter...

Page 2: ...le of electrostatic precipitation Millions of airborne pollutants are carried through the return air ducts of the heating cooling system and treated through four stages of filtration The prefilters 2...

Page 3: ...same time INSTALLATION Static Pressure The static pressure drop across the Air Cleaner will vary with CFM and whether the optional carbon filters have been installed in the unit Location The Air Clean...

Page 4: ...ner If the atomizing type humidifier is installed upstream high humidity salts and minerals may decrease the efficiency of the collecting cells and cause service problems If the atomizing type humidif...

Page 5: ...ent direction than the left to right set up The handle should face the door Close access door Wiring Wiring should only be performed by qualified personnel only All wiring must comply with all applica...

Page 6: ...ith DAX Detergent or a non chlorine non corrosive non abrasive liquid household detergent Allow detergent to run down both sides of plates and ionizing wires Let stand for 5 minutes or fill up laundry...

Page 7: ...age from the power board Measuring High Voltage At Power Board A high voltage meter capable of measuring up to 10 000 VDC is required to test the voltage 1 The Air Cleaner should be ON with the cells...

Page 8: ...oard is turned on and the performance light will come on The light on the power switch will be lit even when the APS is open If the power board fails to come on with the fan on check that the sensor i...

Page 9: ...Cleaner 8 Remove the high voltage meter 9 Replace the power box cover 10 Turn ON the Air Cleaner Setting Approximate Voltage Without High Voltage Meter A high voltage meter should be used to set the...

Page 10: ...ve it from the cabinet 6 If you are removing the power box for any length of time tape a cover over the top opening to prevent air from entering into the system Replacing A Tungsten Ionizing Wire Repl...

Page 11: ...er EAC14 11 EAC22 11 EAC20 11 12 Carbon Filters Set of 3 EAC14 12 EAC20 12 EAC20 12 13 Prefilter EAC14 13 EAC22 13 EAC20 13 14 Cell Guide Plastic EAC14 14 EAC14 14 EAC14 14 15 Collecting Cell EAC14 15...

Page 12: ...needle nose pliers gently pull contacts down or replace contacts Cells arcing excessively power light and per formance indicator light ON or flashing Cells wet from washing Allow cells to dry complete...

Page 13: ...basis for the Air Cleaner to function at its peak of efficiency The frequency of cleaning will vary from one house to another On average the cells should be cleaned every 3 months Use the chart below...

Page 14: ...NOTES 14...

Page 15: ...he defective part to General Filters Inc THERE ARE NOT EXPRESS WARRANTIES COVERING THIS ELECTRONIC AIR CLEANER OTHER THAN AS SET FORTH ABOVE THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A...

Page 16: ...of the furnace or air handler ensure that there is 115 Volt output from these terminals when the unit is run manually and is running on low speed Some manufacturers do not supply full output voltage...