SPECIFICATIONS
Probe Type
Soft metal, with flexible-obedient remote-
controlled neck
Probe Length
1m (3.3 ft.)
Camera Head Diameter, Type
0.23 in. (6mm), Stainless steel
Camera Head Diameter
0.26 in. (6.5mm)
with Thread Protector
Camera Head Length
0.9 in. (23mm)
Camera Resolution
VGA (640 x 480 pixels)
Camera Depth of Field
0.25 to 12 in. (6.4 to 300mm)
Camera Field of View
60° (diagonal)
Camera Lighting
3 forward-facing LEDs
+ 2 side-facing LEDs
Wireless Frequency
Any of four channels centered on 2.4GHz
Wireless Range
33 ft. (10m)
Operating Temperature
-4° to 140°F (-20° to 60°C)
Dimensions of Probe Controller
5.47 x 1.38 x 1.26 in. (139 x 35 x 32mm)
Weight of Controller
7.76 oz. (220g)
OPERATING & MAINTENANCE TIPS
The probe is flexible to make it easy for you to
inspect hard-to-reach areas. Never insert or bend it
by force, and never over-bend any part of the probe.
Specifically:
• Do not bend the last 1 to 2 inches (25 to 50mm) of
the probe by more than 70°
• Do not bend the probe at any other point
by more than 90°
• The probe’s neck is a particularly sensitive area.
Never apply heavy weights or forces to the neck.
Never try to bend the neck by hand; use only the
control wheel. Before storing the probe, straighten
the neck.
9
1 to 2 in.
(25 to 50mm) from tip
2 in. (50mm)
or more from tip