INSTRUCTIONS FOR USE (CONT.)

Ref 300929 Rev. B

05-20

 

4.5 In the systems for hot water production, the

  temperature of the liquid that comes into contact with

  the valve must always be lower than the value stated 

  in this instruction manual and/or indicated on the valve

 itself. 

Avoid the formation of steam or overheated

 water.

 IMPORTANT:

 When the temperature of the liquid is

  close to the maximum value, the outside temperature

  of the valve body is only slightly lower. Therefore,

  take care in case of contact with the hot surface.

 

4.6 After use and/or before performing any operation on the

system or on the valve, release the pressure by using the

adjustment knob/screw and opening the gun or the control 

device for a few seconds. The jet created by the residual 

pressure must be directed downward in order to avoid damage

or injury.

4.7 For safety reasons, it is advisable to equip the high 

pressure feeding line of the system also with a relief or safety

valve duly adjusted.

4.8 To connect the valve to the system it is referable to use

flexible hoses fitted in a way that they do not for 90

0

 elbows,

throttlings or siphons which could include harmful air bubbles.

The inside diameters of the hoses and fittings must be equal to

the correspondent inside diameters of the inlet, by-pass and 

outlet threads of the valve. Moreover, it is necessary to correctly

choose the type of hose depending on the rated pressure and

flow rate; the hoses must always be used within their operation

limits as stated by the manufacturer and indicated on the hoses

themselves.

4.9 Tighten the fittings as follows:

G1” inlet fitting - torque wrench setting 147.5 Ft.lbs.(200 Nm)

G3/4” outlet fitting - torque wrench setting 88.5 Ft.lbs.(120 Nm)

G1-1/4” bypass fitting - torque wrench setting 221.3 Ft.lbs.(300 Nm)

In order to ensure the seal, fit a metal washer with a rubber ring

between the fittings, or use a proper sealant on the thread.

4.10 Always connect the valve by-pass fitting to a hose, in 

order to avoid the excessive noise caused by the water outflow 

through the by-pass without hose.

4.11 Before operating the system, it is advisable to start it for a

preliminary test run in order to check that the system is properly

installed.

4.12 In order to optimize the pump/valve coupling, it is nec-

essary to keep the valve operation, as a function of the pump 

pressure and flow rate, within a maximum power of 81.5 HP. As 

shown in the chart, this means using pumps producing a flow 

rate of approx. 39.6 GPM for maximum working pressures of 

3045 PSI , and generating a pressure of approx. 1958 PSI for 

maximum flow rates of 60.7 GPM.

WARNING: Do not use the valve in the systems covered by 

Directive 97/23/CE (PED) -   Cath

5. MAINTENANCE

5.1 Maintenance and repair must be carried out by qualified and

authorized staff only. Before any operation, make sure that the 

valve and the system are shut down and made unusable.

5.2  A correct maintenance helps extend the working life and 

grants a better performance of the valve.

453 From time to time, it is necessary to check that the valve is

clean outside, and that there is no sign of leakage and/or

malfunctioning. If necessary, replace the involved parts. In case

of doubts, contact GP’s Customer Service Department.

5.4 Replace the valve parts with original spare parts only.

 

IMPORTANT: After maintenance, make sure that the

 valve is re-assembled correctly and that the initial

 conditions are restored. Comply with the torque wrench

 setting values and set the pressure again as described

 above.

4.5 The valve is entirely made of non-toxic and safe materials; 

however, in case of disposal, we suggest you do not dispose of

it in the environment but take it to an authorized disposal center 

or contact the Customer Service Department.

 

The valve shall not be tampered with for any reason

 and/or used for any purpose other than the use it

 has been designed for. In case of tampering, the

 manufacturer disclaims all responsibility as to the

 valve functioning and safety.

6. WARRANTY CONDITIONS

6.1

 The period and conditions of warranty are specified in the 

purchase contract.

6.2

 Warranty is voided in case the valve is used for improper

purposes, used at higher performances than the rated ones,

repaired with non-original spare parts or if it turns out to be

damaged due to the non-compliance with the operating 

instructions or to unauthorized tampering.

Summary of Contents for RA2

Page 1: ... through the by pass Protects the system from over pressurization Traps pressure after the valve while reducing pressure at the pump SPECIFICATIONS FEATURES DIMENSIONS Ref 300929 Rev B 03 19 Part Number RA2 Max Pressure 3 050 PSI Max Flow 61 0 PSI Max Temperature 185 F Port Size Inlet 1 BSP F Outlet 3 4 BSP F Bypass 1 1 4 BSP F Weight 10 6 lbs General Pump is a member of the Interpump Group ...

Page 2: ...Ring 22 x 30 x 1 5 LP 1 16 F36339366 Piston Control 1 17 F36339482 Spacer 1 No Part No Description Qty 18 F90261000 Ring Spacer Ø 15 x 23 x 6 LP 1 19 F36339970 Guide Ring 1 20 90386500 O ring 29 82 x 2 62 1 21 F90517750 Anti extrusion Ring 30 9 x 35 x 1 5 1 22 F36340070 Bushing 1 23 701014 O ring 12 42 x 1 78 1 24 F36339566 Ring 1 25 90385200 O ring 22 22 x 2 62 1 26 F90514450 Anti extrusion Ring ...

Page 3: ...of water equal to 5 of the total flow rate In case the flow rate at the by pass is close to zero or exceeds 15 of the maximum flow rate this could cause failure early wear and result in situations of danger The positions mentioned in the following instructions refer to those shown in the parts list on page 2 3 2 Connect the valve to the water system and follow these steps 3 2 1 Loosen the nut pos ...

Page 4: ...e by pass without hose 4 11 Before operating the system it is advisable to start it for a preliminary test run in order to check that the system is properly installed 4 12 In order to optimize the pump valve coupling it is nec essary to keep the valve operation as a function of the pump pressure and flow rate within a maximum power of 81 5 HP As shown in the chart this means using pumps producing ...

Page 5: ...p Group RA2 Industrial Unloader INSTRUCTIONS FOR USE CONT The valve should be mounted on the pressure line in any position horizontal or vertical which will allow easy access to the pressure adjusting screw For proper oper ation the by pass line internal diameter should be at least 1 25 at the narrowest point and should not be connected directly to the pump inlet line see below for correct instal ...

Reviews: