Page 9
Serial #10127003 and Later
HF SERIES
GENERAL PUMP
A member of the Interpump Group
8. CONNECTIONS AND PLUGS
HF pumps are provided with (Fig. 4):
1 - 2 inlet ports IN Ø 1” NPT
Either inlet port can be used; the one not used must
be hermetically plugged.
2 - 2 outlet ports OUT Ø 3/4” NPT
Fig. 4
9. PUMP INSTALLATION
9.1 Positioning
The pump must be installed on a rigid and perfectly flat and horizontal base by means of the proper four M16 x 1.5
threaded feet. Tighten the screws to 155 ft lbs (210 Nm). The base should be rigid enough to avoid any misalignment or
flexing on the pump/transmission coupling axis due to the torque involved during operation.
The unit should not be rigidly fixed on the floor but be installed upon vibration dampeners. For special applications
contact our technical department.
An eye-bolt is provided on top of the crankcase for easy handling of the pump (see picture below).
Ref 300764 Rev. F
05-21