HF SERIES
Page 8
Serial #10127003 and Later
GENERAL PUMP
A member of the Interpump Group
Check the oil level and top up if necessary using the oil
dipstick pos. 1, Fig. 3.
The correct checking of the oil level is made with the
pump not running, at room temperature. The oil change
must be made with the pump at working temperature,
removing: the oil dipstick, pos. 1, and then the plug pos.
2, fig. 3. The oil check and change must be carried out
as indicated in the table in fig. 14 chapter 11.
The quantity required is 128 oz (3.8 litres).
In any case oil must be changed at least one
a year, as it is degraded by oxidation.
For room temperatures other than 32° F to 86° F (0° C
to 30° C), follow the instructions in the following diagram,
considering that oil must have a minimum viscosity of
180 cSt.
The used oil must be properly disposed of at an authorized
recycling center. Under any circumstances, do not release
used oil into the environment.
Fig. 3
Ref 300764 Rev. F
05-21