Model S800
8
–
The sensor should be protected from coal, or rock damage, water spray, oil and
grease. A splash guard, P/N 10395-1
(UCISC# 544535), is provided for protection
against water, oil and grease.
–
Weld the shock mounting plate furnished by UCISC in location selected prior to
mounting the S800 Monitor.
–
Mount the S800 in place on the shock mounting plate. Bolting will facilitate easy
removal in the event of damage.
3.5
S800 Terminal Connections
All instrument wire connections to the Model S800 are made to the connector located in
the base of the unit’s explosion proof (XP) housing.
The connector accepts 14 or 16 AWG stranded wire. Recommended strip length of the
wire inserted into the connector is shown in Figure 1.
Strip Length
Figure 1: Wire strip Length
Connections to the sensor and power supply are made via terminal blocks which are
designed to accept spade lugged 14 or 16 AWG wire. Follow the color coded wiring
connections in Figure 2.
3.6
Installation Check-Out
Installation of the Model S800 system is now complete.
Recheck all wiring installed in the permissible enclosure and/or the miner control box. Check
to ensure compliance with Figure 2, and the mining machine manual. Ensure that it
conforms to the wiring schematic applicable to the particular installation being made.
Recheck S800 wiring for connection to proper terminals.
Summary of Contents for S800
Page 14: ...Model S800 10 Figure 2 Color Coded Wiring Connections ...
Page 28: ...Model S800 7 4 Module Base Assembly Figure 13 Module Base Assembly 24 ...
Page 29: ...Model S800 7 5 Power Supply Assembly Figure 14 Power Supply Assembly 25 ...
Page 30: ...Model S800 7 6 Detector Housing Assembly Figure 15 Detector Housing Assembly 26 ...