BEFORE ASSEMBLING, MAKE SURE THAT THE SWITCH IS IN THE “OFF” POSITION AND THAT THE POWER CORD IS
UNPLUGGED. DO NOT PLUG IN OR TURN ON THE MACHINE UNTIL YOU HAVE COMPLETED THE ASSEMBLY AND
INSTALLATION STEPS DESCRIBED IN THIS SECTION OF THE MANUAL.
INSTALLING THE TABLE AND THE 90
°
STOP (CONTINUED)
12
3.
Align the four mounting holes in the table with their
corresponding holes in the trunnion.
4.
Starting by the holes located in the right side of
the table, tighten bolts with washers using a 13 mm
wrench.
6.
Tighten the 2 others bolts with washers using a 13
mm wrench.
5.
To facilitate access to the other 2 mounting holes
in the left side, loosen the table lock lever counter-
clockwise and tilt the table by turning the knob
A.
A
6.
Set the table in the horizontal position indicated by
the “O” on the graduated scale. Place a combina-
tion square on the table against the blade, adjust the
table until threre is no space between the square and
the blade, and then tighten the table tilt lock lever
B
.
7.
Loosen the table stop until its head touches the ta-
ble
C
, and then tighten the jam nut
D
while holding
the nut under the frame.
C
D
B