background image

HELPFUL GUIDELINES

PREPARATION FOR REPLANTING

Drain the whole system, brush out the growing chambers and, if necessary, unclog the 
spray holes in the beige spray lines mounted inside the growing chambers. Sponge 
off all parts to disinfect. You can use General Hydroponic’s FloraShield™ to clean the 
system and clay pebbles or a disinfectant. Rinse everything thoroughly. Refill it with 
water and run it for a few hours, then drain again before introducing a new crop. 
Clean filters frequently. Simply unplug pump and remove reusable filter. Rinse pump 
filter under hot water to clean. CAUTION: Do not rinse filter with a strong Bleach 
(chlorine) solution, it may react with the filter and form an oily residue.

OPERATION

When plants are small and their roots are not well developed, the Drain Level Tubes (DLT) 
should be at the maximum height to allow nutrient rich water to reach the bottoms of 
the net cups. Once the roots have grown and are immersed within the flowing stream 
of nutrient, the DLT’s can be pushed down to increase oxygen within the nutrient and 
growing chamber. The water level in the Growing Chambers should be maintained at 
a 1” to 2” depth in case the power or the pump fails. Generally it’s best for the system 
to always run. However, many people do put their AeroFlo

2

 systems on a timer to save 

electricity. The AeroFlo

2

 stays on during the light cycle and only runs for 10 to 15 minutes 

every 1 to 2 hours for the night cycle. Cycling the pump keeps the water from stagnating 
and the roots from drying out and dying.

Summary of Contents for AeroFlo2 18

Page 1: ...AeroFlo2 18 30 Assembly Guide...

Page 2: ...Cover 8 SnapStand Support Legs 2ea 9 SnapStand Base 2ea 10 SnapStand Cross Fitting 2 ea 11 SnapStand Cross Support 12 Clay Pebbles 9 L 13 FloraSeries Nutrients 1 Chambers Box 14 Drain Level Tube DLT 1...

Page 3: ...the Reservoir grommet while supporting the grommet from the inside STEP 2 Connect the Pumpline to the Pump leaving the Swivel Fitting to attach to the Manifold STEP 3 Place the Pump assembly into the...

Page 4: ...e two Support Legs into the SnapStand Bases and the Snapstand Cross Fittings Snap the Cross Support into the SnapStand Cross Fittings STEP 6 Lubricate the end of the DLT with the Lubricant provided an...

Page 5: ...of the water in the Growing Chamber is controlled by the height of the DLT Keep the DLT access covered with the DLT Cover STEP 9 Attach each of the Spraylines to the Manifold and then the Flexible Pum...

Page 6: ...steps Fill the reservoir with a known volume of water and then start the pump Adjust the Drain Level Tubes DLT to the desired level and start adding water in 1 gallon increments until the Growing Cha...

Page 7: ...y plants and higher yields Place the AeroFlo2 system in a warm well lit well ventilated location such as an outdoor garden sunlit window patio or greenhouse Keep your AeroFlo2 away from areas where th...

Page 8: ...h the filter and form an oily residue OPERATION When plants are small and their roots are not well developed the Drain Level Tubes DLT should be at the maximum height to allow nutrient rich water to r...

Page 9: ...t resorting to harsh toxic chemicals FloraShield s unique combination of compounds can thoroughly rinse systems and plants during all phases of growth Growers across the globe have attested to FloraSh...

Page 10: ...ficial microbes that activate when introduced to a plant s root structure This metabolic fuel solution is packed with powerful vitamins complex plant sugars protein building amino acids seaweed extrac...

Page 11: ...ectar ensures optimal metabolic rates during flowering and fruiting phase when nitrogen levels have been reduced FloraNectar also promotes a sturdier plant structure during the vegetative phase when h...

Page 12: ...n the plug matrix results in early root growth Use Rapid Rooter for robust early rooting that supports explosive plant growth Rapid Rooter plugs are available in the following sizes 50 plug tray 50 pl...

Reviews: