background image

CTS12GEN2 RIP-R-STRIPPER

®

 FLOOR COVERING STRIPPER 

FORM GOM11121101US, VERSION 1.2 

 

 

 

 

 

       

English-EN

 

 

15

 

 

 

                      FIGURE 32 

 

15.  Grasp handle grip of RIP-R-STRIPPER firmly in one hand and turn RIP-

R-STRIPPER master ON/OFF switch to ON position with other hand. 

FIGURE 33               

 

                       FIGURE 33 

 

16.  Using proper operator stance, push forward with both hands on operator 

handle to engage accessory tool and initiate breaker action. To stop 

breaker action, reduce forward applied pressure. If extension cord 

becomes entangled about RIP-R-STRIPPER and/or operator turn 

machine ON/OFF switch to OFF position immediately. 

 

NOTE:

 If accessory tool does not properly contact internal breaker anvil, 

breaker blow force will not transmit to tool.  Breaker will function, but floor 

covering cannot be removed. 

 

17.  Consistently remove loose flooring material to determine proper material 

removal depths and extent of work completed. Lack of proper dust 

collection system and/or broom use can increase problem. 

 

 

 

IMPORTANT:

 Properly dispose of all accumulated floor covering materials 

according to international and local environmental regulations.                       

RIP-R-STRIPPER normal use creates material build-up on machine. It is highly 

recommended all exposed internal/external surfaces be properly cleaned after 

each use plus, adjust wheel scraper clearance to minimize material build-up on 

wheels. DO NOT allow materials to build up around breaker.  

 

STOPPING RIP-R-STRIPPER 

 

18.  Turn RIP-R-STRIPPER master ON/OFF and electric breaker ON/OFF 

switch to OFF position between each use and when moving from one 

major section of work surface to another. 

 

19.  Disconnect extension cord/GFI from power source. Never leave RIP-R-

STRIPPER connected to power source and unattended.  

 

20.  Disconnect extension cord/GFI and breaker power cord from RIP-R-

STRIPPER. 

 

11  MAINTENANCE INSTRUCTIONS 

 

For routine maintenance, the following information should be followed at 

minimum once per week or 40 hours of use for maximum performance and 

return on investment unless otherwise indicated. Information is for reference 

only and is not intended to be all inclusive. 

1. 

Use factory approved replacement parts/accessories only for 

maintenance and repair.  

 

2. 

All maintenance/repairs not described in this operator manual must be 

done by a dedicated service center following a specific service/repair 

manual. 

 

3. 

STOP RIP-R-STRIPPER BEFORE performing maintenance per 

STOPPING RIP-R-STRIPPER in OPERATOR INSTRUCTIONS section 

of this manual.   

 

  WARNING

      

 

 

Properly dispose of all accumulated floor covering 

materials per OSHA and EPA codes/regulations. 

 

Many materials can be classified as hazardous requiring 

proper disposal procedures. 

 

Contact applicable government agencies for specific 

information.  

 

  DANGER 

 

DO NOT modify, bypass or disable RIP-R-STRIPPER 

ON/OFF switch on operator handle. 

 

DO NOT operate machine if machine ON/OFF switch on 

RIP-R-STRIPPER and/or breaker is not functioning 

properly. 

 

Such configuration will not allow operator to quickly stop 

RIP-R-STRIPPER in event of an emergency, prevent 

unexpected machine start-up, loss of control and/or 

“runaway” machine and can result in property damage 

and/or personal injury.   

 

  DANGER 

 

Always maintain proper control of RIP-R-STRIPPER. 

 

Accessory tool may begin movement when ON/OFF 

switch is activated. There is no automatic motor shut off 

feature on machine. 

 

If operator loses control, a “runaway” machine can result 

in property damage and/or personal injury. 

 

  WARNING

      

 

 

Operating RIP-R-STRIPPER utilizing components not 

meeting minimum operational standards can result in 

property damage and/or personal injury. 

 

  WARNING 

 

Stop RIP-R-STRIPPER when moving from one major 

section of work surface to another.  

 

DO NOT choose to save time (time required to restart 

machine), money (if RIP-R-STRIPPER is being rented) or 

gain added convenience by electing to keep machine 

running between major sections. 

 

Never leave RIP-R-STRIPPER running and unattended.  

 

Not doing so can result in property damage and/or 

personal injury. 

Summary of Contents for RIP-R-STRIPPER CTS12GEN2

Page 1: ...1 5511 Note There is no charge for Customer Service Internet Address http www generalequip com Email general generalequip com Mailing Address General Equipment Company 620 Alexander Dr S W P O Box 334...

Page 2: ...ions 1926 and 1910 covering construction CAUTION The concept of electrically powered walk behind floor covering removal equipment has been successfully utilized for many years as a practical solution...

Page 3: ...______________________ Owner Instructor __________ Date _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Ope...

Page 4: ...requirements local laws and regulations job site safety plus RIP R STRIPPER maintenance Constantly examine and upgrade program to guarantee owner s and or operator s safety Each operator must be fully...

Page 5: ...s will be required to lift RIP R STRIPPER as demanded by specific job applications When lifting two people are required Utilize proper lifting techniques to minimize fatigue and back related injuries...

Page 6: ...ing and balance at all times DANGER DO NOT attempt carrying lifting lowering RIP R STRIPPER into from transportation vehicle using only one person Use two people or appropriate capacity power tailgate...

Page 7: ...work surface Contact with such objects can lead to loss of machine control resulting in property damage and or personal injury WARNING Exercise extreme caution when operating RIP R STRIPPER on above g...

Page 8: ...er voltage and amperage levels in addition to power source being properly grounded Proper voltage and amperage to electric breaker is essential for maximum productivity and service life Low voltage an...

Page 9: ...our dealer who will assist you in obtaining them NOTE If ordered with RIP R STRIPPER optional chisels blades and accessories can be shipped separately or included in shipping carton NOTE All lubricati...

Page 10: ...uring normal operation b Breaker receiver will normally be located adjacent to a urethane block FIGURE 8 FIGURE 8 NOTE Female hexagon shaped tool receiver orientation to breaker body can vary between...

Page 11: ...proper function as stated in this operator manual and information supplied by breaker manufacturer INSTALLING REMOVING ACCESSORY TOOLS Tools Required None except as noted RIP R STRIPPER is designed to...

Page 12: ...d resulting smoothness of work surface Floor coverings removal process is directly controlled by 1 Tool type impact angle and sharpness 2 Sufficient machine weight and or down force as provided by ope...

Page 13: ...ike those normally used with hand operated scraper products 2 Blades provided by General Equipment Company are available in 5 8 1 2 and 12 inch 127 mm 215 9 mm and 304 8 mm widths Use of specific size...

Page 14: ...n cords are required Each cord must be of proper structural integrity and size AWG to meet applicable National Electric Code and OSHA requirements An additional extension cord with integral GFI can be...

Page 15: ...IPPER without extension cords twist lock connection device and GFI in proper operating condition The GFI is intended as a safety device in event power source has a fault Always assume electrical wirin...

Page 16: ...ed at minimum once per week or 40 hours of use for maximum performance and return on investment unless otherwise indicated Information is for reference only and is not intended to be all inclusive 1 U...

Page 17: ...n is intended for specific service repair situations for the RIP R STRIPPER Information is for reference only and is not intended to be all inclusive 1 Use factory approved replacement parts accessori...

Page 18: ...2 obtaining replacement parts 3 obtaining warranty support 4 troubleshooting 5 short and long term storage Keep this information stored with Operator Manual for RIP R STRIPPER so it will always be av...

Page 19: ...d accessory tool Replace accessory tool Electric breaker receiver out of alignment Realign main wheels to provide for accessory tool contact 14 STORAGE LONG TERM STORAGE Procedure for long term storag...

Page 20: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 19 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 21: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 20 7 Replacement Parts CTS12 RIP R STRIPPER...

Page 22: ...Number Description Quantity 1 2 3 4 SG12 0110 310 0030 SG12 0415 CTS12 0190 Weldment Handle Adjustable Assembly Control Throttle Complete Grip Handle Assembly Lever Brake 1 1 1 1 Replacement Parts Dia...

Page 23: ...erence Number Part Number Description Quantity 1 2 3 4 5 6 7 8 310 0030 010 A 310 0030 020 A 310 0020 030 310 0030 040 310 0030 050 310 0030 060 310 0030 070 310 0030 080 Assembly Body W Screws Includ...

Page 24: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 23...

Page 25: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 24 Replacement Parts Diagram Lower Handle Assembly Up Through Serial Number 153105...

Page 26: ...0 18040000 SG12 0340 17060000 SG12 0170 SG12 0380 SG12 0150 SG12 0160 WS277 SG12 0350 COV 0411 Handle Lower Weldment Knob Bolt Shoulder 5 8 x 1 1 4 Plated Mount Elastomeric Cover Switch Grommet Rubber...

Page 27: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 26 Replacement Parts Diagram Lower Handle Assembly Starting with Serial Number 153106...

Page 28: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 27...

Page 29: ...5 6 7 8 9 10 11 CTS12 0480A CTS12 0470A SG12 0080 SG12 0300 010 SG12 0070 CTS12 0340 WIRE NUT Y SG12 0290A HUB 4720C SG12 0320 FCS16 1000 Cable Electrical Assembly Male Plug to Switch Cable Electrica...

Page 30: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 29...

Page 31: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 30...

Page 32: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 31 Replacement Parts Diagram Latch Tube Assembly Up Through Serial Number 141417...

Page 33: ...CTS12 0130 20040400 CTS12 0150 CTS12 0260 CTS12 0160 CTS12 0270 CTS12 0140 CTS12 0370 SG12 0340 CTS12 0080 CTS12 0360 22000800 CTS12 0210 Bar Latch End Rod Male Tube Spacer Nut Jam 5 8 11 UNC LH Plat...

Page 34: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 33 Replacement Parts Diagram Latch Tube Assembly Starting with Serial Number 141418...

Page 35: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 34 Replacement Parts Diagram Latch Tube Assembly Starting with Serial Number 141418...

Page 36: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 35 Replacement Parts Diagram Upper Frame Assembly...

Page 37: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 36 Replacement Parts Diagram Upper Frame Assembly...

Page 38: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 37 Replacement Parts Diagram Lower Frame Assembly Up Through Serial Number 153105...

Page 39: ...her Plastic Pin Cotter 1 8 x 1 1 2 Bushing Spring Type 62 ID Stand Kick LH Stand Kick RH Pin Clevis 5 8 x 3 ZY Scraper Wheel Nut Hexagon Flange 5 16 18 UNC Plated Screw Cap Socket 10 24 x 5 8 Plated L...

Page 40: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 39 Replacement Parts Diagram Lower Frame Assembly Starting With Serial Number 153106...

Page 41: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 40...

Page 42: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 41 Replacement Parts Diagram Breaker Mount Assembly Bosch 11335K GSH 16 28...

Page 43: ...mber Part Number Description Quantity 1 2 3 4 5 6 7 8 CTS12 1200 CTS12 1001 CTS12 0040 CTS12 0075 CTS12 0320 CTS12 0330 15061000 16060000 Weldment Mount Base Weldment Clamp CAP Cover Hammer Screw Clam...

Page 44: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 43 Replacement Parts Diagram Breaker Mount Assembly DeWalt D25960K...

Page 45: ...Number Description Quantity 1 2 3 4 5 6 7 8 CTS12 1700 CTS12 1701 16060000 CTS12 0040 CTS12 0070 CTS12 0530 CTS12 0520 15060800 Weldment Mount Base Weldment Clamp Cap Washer Lock 3 8 Plated Cover Ham...

Page 46: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 45 Replacement Parts Diagram Breaker Mount Assembly Hilti TE 905 AVR...

Page 47: ...0 CTS12 1001 CTS12 0040 CTS12 0075 CTS12 0310 CTS12 0380 15061000 16060000 Weldment Mount Base Weldment Clamp Cap Cover Hammer Screw Clamp 7 62 L Block Clamp Elastomeric TE 905 AVR Hilti Block Clamp E...

Page 48: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 47 Replacement Parts Diagram Breaker Mount Assembly Hilti TE 1000 AVR...

Page 49: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 48...

Page 50: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 49 Replacement Parts Diagram Breaker Mount Assembly Hitachi H65SD2...

Page 51: ...1200 CTS12 1001 CTS12 0040 CTS12 0075 CTS12 0500 CTS12 0510 15061000 16060000 Weldment Mount Base Weldment Clamp CAP Cover Hammer Screw Clamp 7 62 L Block Clamp Elastomeric H65SD2 Hitachi Block Clamp...

Page 52: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 51 Replacement Parts Diagram Breaker Mount Assembly Makita HM1317CB...

Page 53: ...embly Makita HM1317CB Reference Number Part Number Description Quantity 1 2 3 4 5 6 7 CTS12 1100 CTS12 1101 CTS12 0040 CTS12 0070 CTS12 0490 15060800 16060000 Weldment Mount Base Weldment Clamp Cap Co...

Page 54: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 53 Replacement Parts Diagram Breaker Mount Assembly Makita HM1500B...

Page 55: ...e Number Part Number Description Quantity 1 2 3 4 5 6 7 8 CTS12 1000 CTS12 1001 CTS12 0040 CTS12 0075 CTS12 0310 CTS12 0300 15061000 16060000 Weldment Mount Base Weldment Clamp Cap Cover Hammer Screw...

Page 56: ...CTS12GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM11121101US VERSION 1 2 English EN 55 Replacement Parts Diagram Decals...

Page 57: ...10 GECD 5020 SG12 5030 FCS5 5020 CTS12 5060 CTS12 5070 FCS16 5030 CTS12 5040 CS8 5050 SG12 5020 CTS12 5030 CTS12 5020 SG24 5072 Decal RIP R STRIPPER Decal Caution Transport Decal General Decal Switch...

Reviews: