3.2.2

 

Making electrical connection 

 

Connect positive and negative supply conductors to 

the  APU.  Total  length  of  supply  conductors  should  not 
exceed  5  meters  (15  feet).  Adequate  support,  mechanical 
and  thermal  protection  should  be  provided  to  prevent 
friction  and  consequent  insulation  damage.  Supply 
conductors should be protected with properly sized fuse or 
circuit breaker. 

 

 

  WARNING 

 

 

Compressor  is  pre-charged  with  the  right  amounts  of  oil 
and refrigerant. Do not overfill. 

 

 

When  adding  refrigerant  to  the  system,  do  not  open  the 
high-pressure  manual  valve,  otherwise,  the  AC  system 
would force the refrigerant into refrigerant container, and 
push the lubricating oil out, which will damage the system. 

 
 

 

When  adding  the  lubrication  oil  to  the  compressor,  only 
350ml of POE RB68EP oil should be used. Please use only 
designated  oil  type.  Mixture  of  different  brands  of 
lubrication  oil  will  form  precipitates,  which  will  affect 
compressor lubrication. 

 
 

Summary of Contents for Lynx 1200

Page 1: ......

Page 2: ...oduct Features 5 2 PRINCIPLE OF OPERATION 6 2 1 Electrical Diagram 6 2 2 Plumbing Diagram 7 3 INSTALLATION AND COMMISSIONING 8 3 1 Before the Install 8 3 2 Installation 10 3 2 1 Mounting the Unit 12 3...

Page 3: ...ing Lynx No idle DC rooftop air conditioner This service manual describes installation and operation procedures maintenance recommendations and troubleshooting tips Please read carefully before using...

Page 4: ...1750W 6000BTU ROOFTOP HEAT AND COOL 1 2 Areas of Application Lynx series rooftop air conditioner is designed for use in a wide variety of automotive applications such as mobile homes and RV s utility...

Page 5: ...50 400 400 Cooling Capacity W 1400 1400 1750 1750 Cooling Capacity BTU 4800 4800 6000 6000 EER W W 2 34 2 34 2 22 2 22 Heating Characteristics Heating Capacity W 1400 1750 Heating Capacity BTU 4800 60...

Page 6: ...the following features Variable speed compressor allows proportional cooling while reducing noise and increasing efficiency Short cycling of compressor is no longer a concern Unit uses industry stand...

Page 7: ...info generalcomponents ca 1 800 517 7740 2 PRINCIPLE OF OPERATION 2 1 Electrical Diagram...

Page 8: ...7 Lynx Rooftop 1200 1500 AC User Manual 2 2 Plumbing Diagram...

Page 9: ...rant carrying components of this kit are factory tested for leaks and proven safe Every kit comes pre charged with refrigerant and contains all parts and hardware required for installation AC assembly...

Page 10: ...will void the warranty and will cause equipment malfunctions Do not attempt to repair damaged refrigerant lines Refer to Electrical Code regulations when altering main power feed Special consideration...

Page 11: ...back of the vehicle Roof composition wiring plumbing moving sun roof or load bearing parts cross beams that cannot be disturbed or obstructed Unit should be installed horizontally 8 max onto a flat ev...

Page 12: ...11 Lynx Rooftop 1200 1500 AC User Manual...

Page 13: ...e Unit 1 Make a 380 260mm 15 10 1 4 cut out in the desired location Keep in mind that the cut out is not in the middle of the AC unit but is closer to the front of the vehicle 2 Place the rooftop unit...

Page 14: ...13 Lynx Rooftop 1200 1500 AC User Manual 3 Place flange on the inside and secure it with the bolts provided with the kit Install the sleeve if provided...

Page 15: ...info generalcomponents ca 1 800 517 7740 4 Make electrical connection between the rooftop unit and indoor panel then secure indoor panel to the flange with screws provided with the kit...

Page 16: ...fuse or circuit breaker WARNING Compressor is pre charged with the right amounts of oil and refrigerant Do not overfill When adding refrigerant to the system do not open the high pressure manual valv...

Page 17: ...applied simply run the unit as described in operating instructions Look for abnormal noise vibration or smell Let the unit run continuously at full power for at least twenty minutes If no faults came...

Page 18: ...specified voltage range Power supply cable is undersized Use proper gauge supply lines Incorrect temperature setting Set temperature Refrigerant leak in system Repair leak and add refrigerant Poor coo...

Page 19: ...anel on the unit itself When a button pressed on the remote the unit should beep once to acknowledge the command Use ON OFF power button to turn the unit on and off Use MODE button to switch between C...

Page 20: ...19 Lynx Rooftop 1200 1500 AC User Manual The unit should not be used at temperatures below 5 41 or above 43 110...

Page 21: ...porator coil and fan from dust Clean evaporator condensate drain from clogs Inspect screws and bolts holding the units make sure they are tight Inspect wiring for frays Inspect refrigerant lines and i...

Page 22: ...21 Lynx Rooftop 1200 1500 AC User Manual 7 PARTS LIST...

Page 23: ...ator Fan GC1045 1 7 12 24VDC Rotary Compressor GC1046 1 8 U type plate GC1047 1 9 Compressor driver GC1048 1 10 Condenser unit GC1049 1 11 Condenser bracket GC1050 2 12 Fan grid guard GC1051 2 13 Cond...

Page 24: ...23 Lynx Rooftop 1200 1500 AC User Manual 203 1515 Broadway St Port Coquitlam BC Canada V3C 6M2 1 800 517 7740 1 604 677 6210 info generalcomponents ca June 2020...

Reviews: