GENERATOR SPECIFICATIONS

TYPE .................................................................Two-pole, revolving field
ROTOR INSULATION ..................................................................Class F
STATOR INSULATION .................................................................Class F
TOTAL hARMONIC DISTORTION  ..................................................<5%
TELEPhONE INTERFERENCE FACTOR (TIF) ................................<50
ALTERNATOR ...........................................Self-ventilated and drip-proof
BEARINGS (PRE-LUBED & SEALED) .................................................1
COUPLING .............................................................. Direct, Flexible Disc
LOAD CAPACITY (STANDBY) .......................................................100%

NOTE:  Emergency loading in compliance with NFPA 99, NFPA 
110, paragraph 5-13.2.6.   Generator rating and performance in 
accordance with ISO8528-5, BS5514, SAE J1349, ISO3046 and 
DIN6271 standards.

EXCITATION SYSTEM

DIRECT ............................................................. DC excitation system 

 

Low-velocity brushes and slip rings 

 REGULATION ................................................................... Solid-state 

.................................................................................... +2% regulation 

ENGINE SPECIFICATIONS

MAKE .................................................................................... GENERAC
MODEL ................................................................................. MMC 4G15
CYLINDERS ............................................................................... 4 in-line
DISPLACEMENT ................................................... 1.5 Liter (91.5 cu. in.)
BORE .........................................................................75.5 mm (2.97 in.)
STROKE ........................................................................82 mm (3.23 in.)
COMPRESSION RATIO ..................................................................9.4:1
INTAKE AIR ...............................................................Naturally Aspirated
NUMBER OF MAIN BEARINGS ...........................................................5
CONNECTING RODS .............................................. 4-Drop forged steel
CYLINDER hEAD ..................................................................... S.O.h.C. 
PISTONS ..................................................................... 4-Aluminum Alloy
CRANKShAFT ...........................................................Drop Forged Steel

VALVE TRAIN

LIFTER TYPE ...............................................................Rocker Arm Type
INTAKE VALVE MATERIAL .....................high Temperature Alloy Forged
EXhAUST VALVE MATERIAL ................high Temperature Alloy Forged
VALVE SEATS .....................................................................Replaceable

ENGINE GOVERNOR

 ELECTRONIC ...................................................................... Standard

  FREQUENCY REGULATION, NO-LOAD TO FULL LOAD ... Isochronous
  STEADY STATE REGULATION ...............................................+0.25%

LUBRICATION SYSTEM

TYPE OF OIL PUMP .......................................................................Gear
OIL FILTER .................................................................Full flow, cartridge
CRANKCASE CAPACITY .............................................3.8 Liters (4 qts.)

COOLING SYSTEM

TYPE OF SYSTEM ...................................Pressurized, closed recovery
WATER PUMP ..................................................... Pre-lubed, self-sealing
TYPE OF FAN ............................................................................. Pusher
NUMBER OF FAN BLADES ..................................................................6
DIAMETER OF FAN ....................................................380 mm (15.0 in.)
COOLANT hEATER ............................................................120V, 500 W

FUEL SYSTEM

FUEL

 

Natural Gas or L.P. Vapor ................................................. Standard

 

L.P. Liquid Withdrawal ........................................................ Optional

CARBURETOR .......................................................................Down draft
SECONDARY FUEL REGULATOR ....... Nat. Gas or L.P. Vapor Systems
hOT WATER VAPORIZER..................... L.P. Liquid Withdrawal Systems
AUTOMATIC FUEL LOCKOFF SOLENOID.............................. Standard
OPERATING FUEL PRESSURE VAPOR SYSTEMS ........7" to 15" h

2

O

ELECTRICAL SYSTEM

BATTERY ChARGE ALTERNATOR ............................. 15 Amps at 12 V
STARTER MOTOR ...........................................................................12 V
RECOMMENDED BATTERY ............................(1) - 12 V, 530 CCA, 26F
GROUND POLARITY ................................................................Negative

APPLICATION
& ENGINEERING DATA

GENERATOR FEATURES

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage.  No overload capability is available for this rating.  (All ratings in accordance with 
BS5514, ISO3046 and DIN6271).  Prime (Unlimited Running Time): Applicable for supplying electric power in lieu of commercially purchased power.  Prime power is the maximum power available at 
variable load.  A 10% overload capacity is available for 1 hour in 12 hours.  (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

 

SG010 / SG015

 Four pole, revolving field generator, directly connected to the engine 

shaft through a heavy-duty, flexible disc for permanent alignment.

 Generator meets the temperature rise standards for class "F" 

insulation as defined by NEMA MG1-32.6.

 All prototype models have passed a three-phase symmetrical short 

circuit test to assure system protection and reliability.

 All prototype models are tested for motor starting ability by 

measuring the instantaneous voltage dip with a waveform data 
acquisition system.

 All models utilize an advanced wire harness design for reliable 

interconnection within the circuitry.

 Magnetic circuit, including skewed stator design, provides a minimal 

level of waveform distortion and an electromagnetic interference 
level which meets accepted requirements for standard AM radio, TV, 
and marine radio telephone applications.

 Voltage waveform deviation, total harmonic content of the AC 

waveform, and T.I.F. (Telephone Influence Factor) have been 
evaluated to acceptable standards in accordance with NEMA 
MG1-32.

 Alternator is self-ventilated and drip-proof constructed.

 Fully life-tested protective systems, including "field circuit and 

thermal overload protection" and optional main-line circuit breakers 
capable of handling full output capacity.

 System Torsional acceptability confirmed during Prototype Testing.

 Generac h-100 Digital Control Panel

Summary of Contents for SG010

Page 1: ...HGEAR AND ACCESSORIES Long life and reliability is synonymous with GENERAC POWER SYSTEMS One reason for this confidence is that the GENERAC product line includes its own transfer systems accessories switchgear and controls for total system compatibility INNOVATIVE DESIGN PROTOTYPE TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN Butitdoesn tstopthere Totalcommitmenttoco...

Page 2: ...ATTERY CHARGE ALTERNATOR 15 Amps at 12 V STARTER MOTOR 12 V RECOMMENDED BATTERY 1 12 V 530 CCA 26F GROUND POLARITY Negative APPLICATION ENGINEERING DATA GENERATOR FEATURES Rating definitions Standby Applicable for supplying emergency power for the duration of the utility power outage No overload capability is available for this rating All ratings in accordance with BS5514 ISO3046 and DIN6271 Prime...

Page 3: ...6 1 75 Coolant flow min 60 Hz lit US gal 25 6 6 25 6 6 25 6 6 25 6 6 Heat rejection to coolant 60 Hz BTU hr 48 000 72 000 35 000 53 000 Cooling air flow 60 Hz m3 min cfm 40 883 40 883 40 883 40 883 COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz m3 min cfm 0 8 29 1 2 41 0 6 22 0 9 32 EXHAUST Exhaust flow at rated output 60 Hz m3 min cfm 2 7 96 3 9 137 2 1 75 3 0 32 Max recommended back press...

Page 4: ... Solenoid Low Coolant Temperature Secondary Fuel Regulator N G and L P Low Fuel Pressure Alarm Stainless Steel Flexible Exhaust Connection Battery Charge Alternator Battery Cables Battery Tray Vibration Isolation of Unit to Mounting Base 12 Volt Solenoid Activated Starter Motor Air Cleaner Fan Guard Control Console Radiator Duct Adapter OPTIONAL FUEL ACCESSORIES Flexible Fuel Lines L P Liquid With...

Reviews: