Generac Power Systems PWRell 0009890 Owner'S Manual Download Page 9

Owner’s Manual for Generac PWRcell Battery

5

General Information

Section 2: General Information

Specifications

Description

Units

Generac 

PWRcell 3

Generac  

PWRcell 4

Generac 

PWRcell 5

Generac  

PWRcell 6

Energy

Total Energy

kWh

10

13.5

17

20

Usable Energy

kWh

8.6

11.4

14.3

17.1

Power

Continuous

*

kW

3.4

4.5

5.6

6.7

60 minutes

**

kW

4.2

5.6

7.0

8.4

2 minutes

**

kW

5.0

6.7

8.4

10.0

Battery Modules

Number

-

3

4

5

6

DC Voltage (per module)

VDC

46.8

REbus

Communication Protocol

-

REbus DC Nanogrid

Voltage: Input/Output

***

VDC

360-420

Round-Trip Efficiency (DC to DC)

%

96.5

Temperature

Operating Temperature Limits

°

F (

°

C)

41-113 (5-45)

Recommended Temperature Range

°

F (

°

C)

54-86 (13-30)

Installation Altitude

Maximum Installation Altitude

****

ft (m)

9834 (3000)

Weight

Enclosure

lb (kg)

115 (52)

Installed

lb (kg)

280 (127)

335 (152)

390 (178)

445 (202)

Compliance

UL

-

UL 9540, UL 1973, UL 1642, 

CSA

-

CSA 22.2

*

Full cycle: 0% to 100% to 0% SoC @ 30° C 

** 

Discharge @ 25° C

***

380VDC Nominal

****

Module warranty void if installed above limit.

Specifications are subject to change without notice. Refer to the product specification sheet for complete list.

Summary of Contents for PWRell 0009890

Page 1: ...Loss of life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at...

Page 2: ...ion is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operator and as such are not...

Page 3: ...rial Number Locations 6 Unit Dimensions 6 Component Locations 7 Battery Disconnect Switch 7 Battery Status LED 7 About Generac PWRcell Battery 8 Communication 8 System Operational Modes 8 Inverter Con...

Page 4: ...iv Owner s Manual for Generac PWRcell Battery This page intentionally left blank...

Page 5: ...m on how to correctly start operate and stop the unit in case of emergency Safety Rules The manufacturer cannot anticipate every possible cir cumstance that might involve a hazard The alerts in this m...

Page 6: ...d result in death serious injury and equipment or property damage IMPORTANT NOTE See individual unit specifications for required maintenance and run times pertaining to use Connecting Generac PWRcell...

Page 7: ...ould result in death or serious injury 000155a WARNING Electric shock Only a trained and licensed electrician should perform wiring and connections to unit Failure to follow proper installation requir...

Page 8: ...Shutdown press and hold Shutdown A Safety shutdown LED B will illuminate and LCD screen C will indicate Safety Shutdown has been initiated REbus Inverter Internet Shutdown hold 009656 A C B Figure 1 1...

Page 9: ...Ebus Communication Protocol REbus DC Nanogrid Voltage Input Output VDC 360 420 Round Trip Efficiency DC to DC 96 5 Temperature Operating Temperature Limits F C 41 113 5 45 Recommended Temperature Rang...

Page 10: ...ameplate Record the information from these tags so it is available if the tags are lost or damaged When ordering parts or requesting assistance you may be asked to provide this information A 0009891 F...

Page 11: ...battery monitoring system BMS electronics NOTE Battery Disconnect can be locked in the OFF position if required NOTE Turn Battery Disconnect OFF whenever system will be powered down and left inactive...

Page 12: ...enerac PV Link Optimizers F Grid C Generac PWRcell Battery G Loads D REbus H Protected Loads Communication All communication between REbus devices takes place over the REbus conductors using Power Lin...

Page 13: ...able for Self Supply and other non backup uses but lowers the islanding reserve in the event of an outage Raising this setpoint lowers capacity available for Self Supply and related modes but increase...

Page 14: ...rty damage While in Sleep Mode Generac PWRcell performs Power Searches at regular intervals During a Power Search Generac PWRcell wakes up energizes the REbus Nanogrid and scans for potential sources...

Page 15: ...PWRcell Inverter and charging from the Gen erac PWRcell PV Link and other sources Manual Enable See Figure 2 7 If LED B lights solid red when Battery Disconnect switch is turned ON the Generac PWRcel...

Page 16: ...12 Owner s Manual for Genera PWRcell Battery General Information This page intentionally left blank...

Page 17: ...ed air or water NOTE Allow filter to dry before reinstalling 5 Reinstall filter If air filter is damaged contact Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www gen erac com for...

Page 18: ...Dealer shall prepare a written decommissioning plan that provides the overview of the decommissioning process developed specifically for the Generac PWRCell Battery system that is to be decommissioned...

Page 19: ......

Page 20: ...ghts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...

Reviews: