Safety Rules & General Information

2

Owner’s Manual for Generac PWRCell Battery

General Hazards

Automatic start-up. Disconnect utility power and 
render unit inoperable before working on unit. 
Failure to do so will result in death or serious injury.

(000191)

DANGER

WARNING

Risk of injury. Do not operate or service this machine 
if not fully alert. Fatigue can impair the ability to 
service this equipment and could result in death or 
serious injury.

(000215)

(000209b)

WARNING

Loss of life. This product is not intended to 
be used in a critical life support application. 
Failure to adhere to this warning could result 
in death or serious injury.

(000598)

WARNING

Equipment damage. Connect only to REbus-compatible 
devices. Never connect to any other power source.
Connecting to other power sources could result in 
equipment damage.

(000182a)

WARNING

Equipment damage. Only qualified service personnel may 
install, operate, and maintain this equipment. Failure to 
follow proper installation requirements could result in death, 
serious injury, and equipment or property damage.

IMPORTANT NOTE: See individual unit specifications 
for required maintenance and run times pertaining to 
use.

Connecting Generac PWRcell to the electric utility 
grid  must  only  be  done  after  receiving  prior 
approval from the utility company.

Competent,  qualified  personnel  should  install, 
operate, and service this equipment. Strictly com-
ply to local, state, and national electrical and build-
ing codes. When using this equipment, comply with 
regulations  established  by  the  National  Electrical 
Code  (NEC),  CSA  Standard;  the  Occupational 
Safety  and  Health Administration  (OSHA),  or  the 
local agency for workplace health and safety.

Protection  against  lightning  surges  in  accordance 
with local electric codes is the responsibility of the 
installer.

If  working  on  this  equipment  while  standing  on 
metal or concrete, place insulative mats over a dry 
wood platform. Work on this equipment only while 
standing on such insulative mats.

Never  work  on  this  equipment  while  physically  or 
mentally fatigued.

Any  voltage  measurements  should  be  performed 
with a meter that meets UL3111 safety standards, 
and meets or exceeds overvoltage class CAT III.

Summary of Contents for PWRell 0009890

Page 1: ...Loss of life This product is not intended to be used in a critical life support application Failure to adhere to this warning could result in death or serious injury Register your Generac product at...

Page 2: ...ion is performed promptly and to have the equipment checked periodically by an ASD Normal maintenance service and replacement of parts are the responsibility of the owner operator and as such are not...

Page 3: ...rial Number Locations 6 Unit Dimensions 6 Component Locations 7 Battery Disconnect Switch 7 Battery Status LED 7 About Generac PWRcell Battery 8 Communication 8 System Operational Modes 8 Inverter Con...

Page 4: ...iv Owner s Manual for Generac PWRcell Battery This page intentionally left blank...

Page 5: ...m on how to correctly start operate and stop the unit in case of emergency Safety Rules The manufacturer cannot anticipate every possible cir cumstance that might involve a hazard The alerts in this m...

Page 6: ...d result in death serious injury and equipment or property damage IMPORTANT NOTE See individual unit specifications for required maintenance and run times pertaining to use Connecting Generac PWRcell...

Page 7: ...ould result in death or serious injury 000155a WARNING Electric shock Only a trained and licensed electrician should perform wiring and connections to unit Failure to follow proper installation requir...

Page 8: ...Shutdown press and hold Shutdown A Safety shutdown LED B will illuminate and LCD screen C will indicate Safety Shutdown has been initiated REbus Inverter Internet Shutdown hold 009656 A C B Figure 1 1...

Page 9: ...Ebus Communication Protocol REbus DC Nanogrid Voltage Input Output VDC 360 420 Round Trip Efficiency DC to DC 96 5 Temperature Operating Temperature Limits F C 41 113 5 45 Recommended Temperature Rang...

Page 10: ...ameplate Record the information from these tags so it is available if the tags are lost or damaged When ordering parts or requesting assistance you may be asked to provide this information A 0009891 F...

Page 11: ...battery monitoring system BMS electronics NOTE Battery Disconnect can be locked in the OFF position if required NOTE Turn Battery Disconnect OFF whenever system will be powered down and left inactive...

Page 12: ...enerac PV Link Optimizers F Grid C Generac PWRcell Battery G Loads D REbus H Protected Loads Communication All communication between REbus devices takes place over the REbus conductors using Power Lin...

Page 13: ...able for Self Supply and other non backup uses but lowers the islanding reserve in the event of an outage Raising this setpoint lowers capacity available for Self Supply and related modes but increase...

Page 14: ...rty damage While in Sleep Mode Generac PWRcell performs Power Searches at regular intervals During a Power Search Generac PWRcell wakes up energizes the REbus Nanogrid and scans for potential sources...

Page 15: ...PWRcell Inverter and charging from the Gen erac PWRcell PV Link and other sources Manual Enable See Figure 2 7 If LED B lights solid red when Battery Disconnect switch is turned ON the Generac PWRcel...

Page 16: ...12 Owner s Manual for Genera PWRcell Battery General Information This page intentionally left blank...

Page 17: ...ed air or water NOTE Allow filter to dry before reinstalling 5 Reinstall filter If air filter is damaged contact Generac Customer Service at 1 888 GENERAC 1 888 436 3722 or visit www gen erac com for...

Page 18: ...Dealer shall prepare a written decommissioning plan that provides the overview of the decommissioning process developed specifically for the Generac PWRCell Battery system that is to be decommissioned...

Page 19: ......

Page 20: ...ghts reserved Specifications are subject to change without notice No reproduction allowed in any form without prior written consent from Generac Power Systems Inc Generac Power Systems Inc S45 W29290...

Reviews: