Owner’s Manual for Mobile Light Tower
15
Operation
2.
See
. Check both sets of mast cables for
excessive wear or damage. Verify the cables are
properly centered in each pulley (A). Check the
electrical cord for damage.
3.
Press and hold the winch control toggle switch (B)
upward to telescope the mast to the desired height.
Extend the mast slowly, verifying the coiled
electrical cord is extending at the top sections of
the mast.
IMPORTANT NOTE: GMASD immediately if the mast
hangs up or the winch cable develops slack.
4.
The mast can be rotated by loosening the mast
rotation knob at the bottom of the mast (D). Turn
the mast until the lights face in the desired direction
and then tighten the knob.
Starting the Unit
NOTE:
If the engine was run out of fuel or the fuel tank
was drained, it may be necessary to bleed the fuel lines.
Refer to the engine operator’s manual supplied with the
unit.
1.
See
. Verify the main circuit breaker and
individual circuit breakers for each of the lights are
OFF (O).
NOTE:
If the red light on the control panel TURN MAIN
BREAKER OFF is illuminated when the key is turned to
the START position, the breaker is closed (switched on)
and must be turned OFF (O).
Figure 3-3. Circuit Breakers in OFF (O) Position
2.
See
. Turn the key on the Engine Start
switch to the left GLOW PLUG position and hold
the key in place for 10-15 seconds or until the glow
plug indicator turns red. (Kubota units do not have
a glow plug indicator.)
Figure 3-4. Activate Glow Plug
3.
See
. Turn the key to the right START
position and hold it until the engine cranks and
starts running.
NOTE:
For cold weather conditions, refer to the engine
operator’s manual for appropriate glow plug interval.
NOTE:
If oil pressure is not obtained within 15 seconds
after the key is switched to the RUN position, the low oil
automatic shutdown will turn off the fuel supply, stopping
the engine. Check the oil level and turn the key to the
OFF position to reset the oil pressure timer before
attempting to restart the engine.
WARNING
Tipping hazard. Do not extend the mast beyond the
colored mark on the second mast section. The unit
can become unstable and tip or fall, causing injury.
(000262)
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
(000279)
Personal injury or equipment damage. Do not raise
or lower the mast while the unit is operating.
Doing so can break the lenses and cause the
lamps to shatter.
WARNING
WARNING
Equipment Damage. Never start the engine with
circuit breakers switched on. Any load connected
to the generator at start up will cause severe
damage or destroy the generator.
(000368)
I
O
I
O
I
O
I
O
003791
GLOW
PLUG
OFF
RUN
START
003792
CAUTION
(000230)
Equipment Damage. Do not continuously crank
engine for more than ten seconds. Doing so will lead
to overdischarge of batteries and starter seizure.
Summary of Contents for MLT4060KV
Page 4: ...iv Owner s Manual for Mobile Light Tower Trailer Lights Wiring 33 ...
Page 24: ...20 Owner s Manual for Mobile Light Tower Operation This page intentionally left blank ...
Page 35: ...Owner s Manual for Mobile Light Tower 31 Wiring Diagrams DC Wiring Electric Winch ...
Page 36: ...32 Owner s Manual for Mobile Light Tower Wiring Diagrams DC Wiring for Optional Equipment ...
Page 38: ...34 Owner s Manual for Mobile Light Tower Wiring Diagrams This page intentionally left blank ...
Page 39: ......