![Generac Power Systems MAGNUM MLT4060MVD Owner'S Manual Download Page 39](http://html1.mh-extra.com/html/generac-power-systems/magnum-mlt4060mvd/magnum-mlt4060mvd_owners-manual_2208957039.webp)
Operation
Owner’s Manual for MLT4060MVD Light Tower
35
5. After the unit shuts down, move the Control Power
switch to the OFF (O) position.
NOTE:
Disconnect the battery if the unit is to be stored
for an extended period. Refer to the engine operator’s
manual for additional extended storage procedures.
Automatic Shutdown
This unit is equipped with a low oil pressure and high
coolant temperature automatic shutdown system. This
system will automatically shut off the fuel supply to stop
the engine if oil pressure drops too low or the engine
exceeds normal operating temperature. Return the
Control Power switch to the STOP position to reset the
unit after the cause of shutdown has been determined.
Emergency Stop
See
. The unit is equipped with one
emergency stop button, clearly labeled “EMERGENCY
STOP.” The button can be accessed and activated with
all doors closed and locked.
Activate the emergency stop button by pushing it in until
it locks down. This trips the main circuit breaker, which
will open the contact and disconnect the load to the
connection lugs. An emergency stop also opens the fuel
circuit, shutting down the engine. The emergency stop
fault will be displayed on the control panel.
Figure 3-8. Emergency Stop Switch
The emergency stop button will remain locked until it is
pulled out.
NOTE:
To shut down the unit under any other
circumstances, refer to
Lowering Mast—Manual Winch
1. Shut down the lights and engine. See
.
2. Lower the mast.
3. Use the winch handles to collapse the mast to its
lowest position. Verify that the electrical cord does
not get caught in, or pinched by, the mast while it is
being lowered.
IMPORTANT NOTE: Contact an ASD immediately if
the mast hangs up or the winch cable develops
slack.
4.
See
. If the unit is going to be moved,
rotate the mast so the lights face the rear of the unit.
Figure 3-9. Stowed (Travel) Position
To rotate the mast:
a. Loosen the mast rotation knob.
b. Rotate the mast until the white arrows are
aligned and the metal stop tabs are touching.
c. Tighten the mast rotation knob.
Lowering Mast—Electric Winch
(if equipped)
Electrically Lowering Mast
NOTE:
Control power must be on to lower the mast with
the electric winch.
1. Shut down the lights and engine. See
.
2. Press and hold the winch control switch downward
to collapse the mast to its lowest position. Verify
the electrical cord does not get caught in, or
pinched by, the mast while it is being lowered.
CAUTION
(000246)
Equipment Damage. The emergency stop switch is
not to be used to power down the unit under normal
operating circumstances. Doing so will result in
equipment damage.
WARNING
Personal Injury. Stop immediately if the mast hangs
up or the winch cable develops slack. Excess slack
could cause the mast to collapse, resulting in personal
injury or equipment damage.
(000265)
Summary of Contents for MAGNUM MLT4060MVD
Page 11: ...Introduction and Safety Owner s Manual for MLT4060MVD Light Tower 7 Figure 1 1 External Decals...
Page 42: ...Operation 38 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Page 48: ...Maintenance 44 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Page 55: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 51 Accessories...
Page 56: ...Electrical Drawings 52 Owner s Manual for MLT4060MVD Light Tower Optional Accessories...
Page 57: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 53...
Page 58: ...Electrical Drawings 54 Owner s Manual for MLT4060MVD Light Tower...
Page 60: ...Electrical Drawings 56 Owner s Manual for MLT4060MVD Light Tower...
Page 62: ...Electrical Drawings 58 Owner s Manual for MLT4060MVD Light Tower Components Located in LED Box...
Page 65: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 61 AC Schematic...
Page 66: ...Electrical Drawings 62 Owner s Manual for MLT4060MVD Light Tower Relays p 1...
Page 67: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 63 Relays p 2...
Page 68: ...Electrical Drawings 64 Owner s Manual for MLT4060MVD Light Tower DC Connections p 1...
Page 69: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 65 DC Connections p 2...
Page 70: ...Electrical Drawings 66 Owner s Manual for MLT4060MVD Light Tower...
Page 71: ......