Owner’s Manual for MLT4060MVD Light Tower
25
Section 3: Operation
Light Tower Setup
Figure 3-1. Set Up Outriggers and Jacks
1. For maximum light coverage, position the unit at
ground level or in a spot higher than the area being
illuminated by the lamps.
NOTE:
The mast extends up to 23 ft (7 m).
2. See
. Place the unit on firm ground that
is relatively flat, and then block the wheels (A) to
keep it from moving. This will make it easier to level
the unit.
3. Pull the locking pin (B) on the tongue jack and
rotate the jack 90°. Reinstall the locking pin. Turn
the jack handle clockwise to raise the trailer tongue
off of the towing vehicle.
4. A grounding stud (C) is located on the control box.
For grounding requirements, follow any local, state,
or National Electrical Code (NEC) guidelines.
5. See Detail E. Pull the locking pin (D) on the
outrigger (E) and pull each outrigger out until the
spring loaded locking pin snaps back into place.
Pull the locking pin on the outrigger jack and rotate
each jack 90° so the jack pad is facing down.
Reinstall the locking pin.
6. Pull the locking pin on the rear jack (F) and rotate
the jack 90°. Reinstall the locking pin. Rotate the
jack handle clockwise to start leveling the trailer
(see Detail G). Adjust all four jacks by rotating their
handles (G) clockwise until they are firmly in
contact with the ground and the trailer is as level as
possible.
7. See Detail H. Before raising the mast, it may be
necessary to adjust the lamps. The lamps may be
adjusted up, down, left or right by simply aiming
them in the desired direction.
HANDLE
DETAIL E
DETAIL C
DETAIL G
DETAIL H
Rear of Unit
H
J
G
B
D
E
G
A
C
F
(000260a)
High Voltage. Verify area above unit is clear
of overhead wires and obstructions. Contact
with high-voltage power lines will result in
death or serious injury.
DANGER
Summary of Contents for MAGNUM MLT4060MVD
Page 11: ...Introduction and Safety Owner s Manual for MLT4060MVD Light Tower 7 Figure 1 1 External Decals...
Page 42: ...Operation 38 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Page 48: ...Maintenance 44 Owner s Manual for MLT4060MVD Light Tower This page intentionally left blank...
Page 55: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 51 Accessories...
Page 56: ...Electrical Drawings 52 Owner s Manual for MLT4060MVD Light Tower Optional Accessories...
Page 57: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 53...
Page 58: ...Electrical Drawings 54 Owner s Manual for MLT4060MVD Light Tower...
Page 60: ...Electrical Drawings 56 Owner s Manual for MLT4060MVD Light Tower...
Page 62: ...Electrical Drawings 58 Owner s Manual for MLT4060MVD Light Tower Components Located in LED Box...
Page 65: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 61 AC Schematic...
Page 66: ...Electrical Drawings 62 Owner s Manual for MLT4060MVD Light Tower Relays p 1...
Page 67: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 63 Relays p 2...
Page 68: ...Electrical Drawings 64 Owner s Manual for MLT4060MVD Light Tower DC Connections p 1...
Page 69: ...Electrical Drawings Owner s Manual for MLT4060MVD Light Tower 65 DC Connections p 2...
Page 70: ...Electrical Drawings 66 Owner s Manual for MLT4060MVD Light Tower...
Page 71: ......