Stopping the Engine

• Unplug all electrical loads from generator panel

receptacles. Never start or stop engine with electrical
devices plugged in and turned on.

• Put the idle control switch in the “Off” position.

• Let engine run at no–load for 30 seconds to stabilize the

internal temperatures of engine and generator.

• Move run/stop switch to “Stop”.

• Close the fuel shut–off valve.

Operating Automatic Idle Control

This switch is designed to greatly improve fuel economy.
When this switch is turned ON, the engine will only
run at its normal high governed engine speed when an
electrical load is connected.When an electrical load is
removed, the engine will run at a reduced speed. With the
switch off
, the engine will run at the normal high engine
speed. Always have the switch off when starting and
stopping the engine.

Charging a Battery

WARNING!

Storage batteries give off explosive

hydrogen gas while recharging. An explosive mixture
will remain around the battery for a long time after
it has been charged.The slightest spark can ignite
the hydrogen and cause an explosion, resulting in
blindness or other serious injury.

WARNING!

Do Not permit smoking, open

flame, sparks or any other source of heat around a
battery.Wear protective goggles, rubber apron and
rubber gloves when working around a battery.
Battery electrolyte fluid is an extremely caustic
sulfuric acid solution that can cause severe burns. If
spill occurs flush area with clear water immediately.

Your generator has the capability of recharging a discharged
12 Volt automotive or utility style storage battery. Do Not
use the unit to charge any 6 Volt batteries. Do Not use the
unit to crank an engine having a discharged battery.

To recharge 12 Volt batteries, proceed as follows:

• Check fluid level in all battery cells. If necessary, add

ONLY distilled water to cover separators in battery cells.
Do Not use tap water.

• If the battery is equipped with vent caps, make sure they

are installed and are tight.

• If necessary, clean battery terminals.

• Connect battery charge cable connector plug to panel

receptacle identified by the words “12 VOLTS D.C.”

• Connect battery charge cable clamp with red handle to

the positive (+) battery terminal (Figure 9).

• Connect battery charge cable clamp with black handle

to the negative (–) battery terminal (Figure 9).

• Start engine. Let the engine run while battery recharges.

• When battery has charged, shut down engine

NOTE: Use an automotive hydrometer to test battery
state of charge and condition. Follow the hydrometer
manufacturer’s instructions carefully. Generally, a battery is
considered to be at 100% state of charge when specific
gravity of its fluid (as measured by hydrometer) is 1.260 or
higher.

Figure 9 — Battery Connections

Summary of Contents for 6500EXL

Page 1: ...ll safety messages that follow this symbol to avoid possible injury or death Model No 9798 2 6 500 Watt AC Generator Manual No B2649 Revision 3 06 01 2001 Visit our Generac website www generac portabl...

Page 2: ...ironmental Protection Agency For warranty information refer to the engine owner s manual SAFETY RULES This generator set was designed and manufactured for specific applications Do Not attempt to modif...

Page 3: ...f clearance on all sides of generator even while operating unit outdoors or you could damage the unit Never start or stop the unit with electrical loads connected to receptacles with the connected dev...

Page 4: ...erator from the shipping carton CARTON CONTENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Electric start battery cables Generat...

Page 5: ...ning or hot Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Always allow room for fuel expansion Use regular UNLEADED gasoline with the generator eng...

Page 6: ...ker to protect the generator against electrical overload Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for proper grounding of unit Idle Control Switch With this switch set to ON p...

Page 7: ...away from the valve cover and under the arrow NOTE If engine fails to start after 3 pulls move the choke lever to Half choke position and pull starter rope again 2 times NOTE If the engine still fails...

Page 8: ...tive goggles rubber apron and rubber gloves when working around a battery Battery electrolyte fluid is an extremely caustic sulfuric acid solution that can cause severe burns If spill occurs flush are...

Page 9: ...from wind and elements Enclosure should hold enough heat created by the generator to prevent problems CAUTION Never run unit indoors Do Not enclose generator any more than shown RECEPTACLES 120 240 Vo...

Page 10: ...of current Use cord sets that are rated for 125 Volt AC loads at 20 Amps or greater 12 Volt DC 10 Amp Receptacle This receptacle allows you to recharge a 12 Volt automotive or utility style storage ba...

Page 11: ...f power lasts for only a few seconds when starting such motors Be sure you allow for this high starting wattage when selecting electrical devices to connect to your generator First figure the watts ne...

Page 12: ...ean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor...

Page 13: ...Out of gasoline 4 Stale gasoline 5 Spark plug wire not connected to spark plug 6 Bad spark plug 7 Water in gasoline 8 Overchoking 9 Excessively rich fuel mixture 10 Intake valve stuck open or closed...

Page 14: ...Generac Portable Products 6500EXL Extended Life Generator 14 SCHEMATIC...

Page 15: ...Generac Portable Products 6500EXL Extended Life Generator 15 WIRING DIAGRAM...

Page 16: ...Generac Portable Products 6500EXL Extended Life Generator 16 EXPLODED VIEW MAIN UNIT...

Page 17: ...ET Tank 40 78831B 4 HHCS M6 1 0 x 60 SEMS 41 80270 1 VALVE Tank 42 78299 1 BUSHING Plastic Tank 43 B4363 1 CAP Fuel Gauge 44 B1998 1 TANK Fuel 7 Gal Assy Includes 41 42 45 B92039 1 SHIELD Heat Item Pa...

Page 18: ...V 10 75207A 2 CIRCUIT BREAKER 30A 11 75207 2 CIRCUIT BREAKER 20A 12 23365 6 WASHER 8 Shakeproof 13 68868 1 OUTLET 120 Volt 30A Locking Item Part Qty Description 14 43437 1 OUTLET 120V 240V 30A Locking...

Page 19: ...Generac Portable Products 6500EXL Extended Life Generator 19 NOTES...

Page 20: ...mal maintenance and service and does not apply to a generator set alternator or parts which have been subjected to improper or unauthorized installation or alteration misuse negligence accident overlo...

Reviews: