6
Owner’s Manual for Portable Generator
Know Your Generator
Replacement owner’s manuals are available
at www.generac.com.
Emissions
The United States Environmental Protection
Agency (US EPA) (and California Air
Resources Board (CARB), for engines/equip
-
ment certified to California standards) requires
this engine/equipment to comply with exhaust
and evaporative emissions standards. Locate
the emissions compliance decal on the engine
to determine applicable standards. See the
included emissions warranty for emissions
warranty information. Follow the maintenance
specifications in this manual to ensure the
engine complies with applicable emissions
standards for the duration of the product’s life.
(000100a)
WARNING
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
Product Specifications
Generator Specifications
Rated Power
3.3 kW**
Surge Power
3.75 kVA
Rated AC Voltage
120/240
Rated AC Load
Current @ 240V
Current @ 120V
13.75 Amps**
27.5 Amps**
Rated Frequency
60 Hz @ 3600 RPM
Phase
Single Phase
Unit Weight (dry)
111.4 lbs. (50.5 kg)
** Operating Temperature Range: -18 deg. C (0 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi
-
ent temperature, altitude, engine condition, etc.. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60°
F) ambient temperature.
Engine Specifications
Displacement
208 cc
Spark Plug Part No.
0H33750169
Spark Plug Type
F6TC, NGK BP6IS or Champion RN11YC
Spark Plug Gap
0.76 mm (0.030 inch)
Gasoline Capacity
13.2 L (3.5 gal)
Oil Type
Section
Oil Capacity
0.6 L (0.63 qt)
Run Time at 50% Load
10.25 Hours