Generac Portable Products 1,700 PSI Pressure Washer
13
1.
Detach spray gun from high pressure hose. Detach
nozzle extension from spray gun and remove o-ring
and screen from nozzle extension. Flush the screen,
spray gun, and nozzle extension with clean water to
clear debris.
2.
If the screen is damaged, the o-ring kit contains a
replacement in-line filter screen and an o-ring. If
undamaged, reuse screen.
3.
Place the in-line filter screen into the threaded end of
the nozzle extension. Direction does not matter. Push
the screen in with the eraser end of a pencil until it
rests flat at the bottom of the opening. Take care to
not bend the screen.
4
Place the o-ring into the recess. Push the o-ring snugly
against the in-line filter screen.
5.
Assemble the nozzle extension to the spray gun, as
described earlier in this manual.
Purge Pump of Air and
Contaminants
To remove air from the pump, follow these steps:
• Set up the pressure washer as described in “Preparing
Pressure Washer for Use” and connect the water supply.
• Pull the trigger on the spray gun and hold.
To remove contaminants from the pump, follow
these steps:
• Set up the pressure washer as described in “Preparing
Pressure Washer for Use” and connect the water supply.
• Start the engine according to instructions in “How To
Start Your Engine”.
• Squeeze the trigger on the spray gun and hold.
• When the water supply is steady and constant, engage
the safety latch and attach the nozzle extension.
Cleaning Chemical Siphon Tube
If you have used the chemical siphon tube you must flush it
with clean water before stopping the engine.
• Place chemical siphon tube filter into a bucket full of
clean water.
• Flush for five minutes.
• Shut off the engine.
IMPORTANT: Simply shutting OFF engine will not
release pressure in the system. When engine has shut
down, squeeze the trigger on the spray gun to relieve
the pressure in the hose.
Nozzle Maintenance
If an adjustable nozzle becomes restricted or clogged with
foreign materials, such as dirt, a pulsing sensation during
use may occur. If pulsing occurs or the nozzle becomes
partially restricted, immediately clean the nozzle with the
kit included with your pressure washer.
To clean the nozzle:
• Shut off the engine and turn off the water supply.
• Detach the nozzle extension from the spray gun.
• Adjust the nozzle extension to the stream position.
• Remove nozzle from the end of the nozzle extension
(Figure 17) using a 2mm or 5/64 allen wrench (included
in the kit).
Figure 17 — Remove and Clean Nozzle