background image

and compensate your monitors and 
subwoofers. 

If you want, you can save the acoustic 

calibration settings into the monitors, 
subwoofers, and 9301A units. This enables 
the use of the calibration data with the 
GLM network disconnected. Removing the 
GLM network cable and powering down 
and up the 9301A and other products on 
the network enables the use of the stored 
settings. The settings can be stored into 
the 9301A using the Genelec Loudspeaker 
Manager software menu item “Store | Store 
the Current Group Settings…”. 

To operate the system without having the 

computer connected on the GLM network, 
remove the USB cable connecting to the 
GLM adapter, power down and then up the 
9301A and other devices on your system. 
This enables the stored settings. Please 
note that the monitors and subwoofers have 
a switch for selecting the use of the stored 
settings, and this switch must be set ON. 

Returning to factory settings

The room specific settings stored in a 9301A 
can be erased by keeping the power switch 
depressed for more than 10 seconds. This 
returns the 9301A to the factory settings.   

Operating Environment

The 9301A is designed for indoor 
use only. The permissible ambient 
temperature is 15-35 degrees Celsius 
(50-95°F) and relative humidity 20% to 
80% (noncondensing). When the product 
has been stored or transported in cool 
environment and is taken into a warm 
room, wait 0.5-1 hours before opening 
any packing to prevent condensation 
of humidity before connecting to mains 
power. Sufficient cooling must be ensured. 
No minimum clearance is needed.

Maintenance

There are no user serviceable parts inside 
the 9301A. Maintenance or repair must 
only be done by Genelec certified service 
personnel. 

Guarantee

Genelec guarantees the 9301A for two years 
against manufacturing faults or defects 
altering performance. Refer to the reseller 
for full sales and guarantee terms.

 Safety Considerations

The 9301A has been designed in accordance 
with international safety standards. To ensure 
safe operation, the following warnings and 
precautions must be observed:

•  Servicing and adjustment must only 
be performed by Genelec certified service 
personnel. 
•  The enclosure must not be opened.
•  Do not use this product with a mains 
cable or mains outlet having no protective 
earth (potential equalizing) connection as 
doing so may result in personal injury.  
•  To prevent fire or electric shock, do not 
expose the unit to water or moisture. 
•  Do not place objects filled with liquid, 
such as vases, on the 9301A or near it. 
•  The 9301A is not completely 
disconnected from the mains power unless 
the mains cable is removed from the device 
or the mains outlet.

Compliance to FCC Rules

This device complies with part 15 of the FCC 
Rules. Operation is subject to the following 
two conditions: 

•  This device may not cause harmful 
interference, and
•  This device must accept any interference 
received, including interference that may 
cause undesired operation. 

Note: This equipment has been tested and 
found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC 
Rules. These limits are designed to provide 
reasonable protection against harmful 
interference in a residential installation. This 
equipment generates, uses, and can radiate 
radio frequency energy and, if not installed 
and used in accordance with the instructions, 
may cause harmful interference to radio 
communications. There is no guarantee that 
interference will not occur in a particular 
installation. If this equipment does cause 
harmful interference to radio or television 
reception, which can be determined by 
turning the equipment off and on, the user is 
encouraged to try and correct the interference 
by one or more of the following measures: 

•  Reorient or relocate the receiving 
antenna. 
•  Increase the separation between the 

equipment and receiver. 
•  Connect the equipment into an outlet 
on a circuit different from that to which the 
receiver is connected. 
•  Consult the dealer or an experienced 
radio/TV technician for help.

Modifications not expressly approved 

by the manufacturer can void the user’s 
authority to operate the equipment under 
FCC rules.

Summary of Contents for 9301A

Page 1: ...Genelec 9301A Multichannel AES EBU Interface Operating Manual 9301A ...

Page 2: ...LM network cable and an operating manual Before connecting up ensure that the mains power is switched off The energy saving Intelligent Signal Sensing ISS function can be turned on in the 9301A to put it automatically into a power save state when no AES EBU input signal is present In the power save state the 9301A consumes less than one watt of power Upon sensing an AES EBU input signal the Figure...

Page 3: ...AL IN AES IN 2 AES IN 3 AES IN 4 LFE 7 1 CHANNEL AUDIO SOURCE AES OUT 1 AES OUT 2 AES OUT 3 AES OUT 4 SUBWOOFER LINK AES EBU DIGITAL CABLING GLM NETWORK CABLING POSSIBLE DAISY CHAINED ADDITIONAL SUBWOOFERS AES IN 1 AES IN 2 AES IN 3 AES IN 4 LFE 7 1 4 CHANNEL AUDIO SOURCE GLM ADAPTER AES IN 1 AES IN 2 AES IN 3 AES IN 4 LFE AES EBU DIGITAL CABLING GLM NETWORK CABLING 7 1 4 Figure 3 Audio and GLM ne...

Page 4: ...he mains input supports a wide mains voltage range 100 240 VAC 50 60 Hz and enables the 9301A to be plugged in anywhere globally If the mains power is provided with a generator inverter or certain lower quality UPS devices we recommend filtering of the mains power voltage harmonics and taking care that the voltage supply is stable Controls And Adjustments On the outside of the unit there are a pow...

Page 5: ...d green Power on normal state and operation Blinking green GLM is adjusting the 9301A Green blink every 10 seconds The 9301A is in ISS power saving state No light Power off Input signal indicator light Solid green Valid AES EBU signal detected receiving No light No input detected Table 1 Front panel indicator light functions SPECIFICATIONS Weight 2 kg 4 4 lbs Dimensions Height Width Depth 44 mm 1 ...

Page 6: ...fety standards To ensure safe operation the following warnings and precautions must be observed Servicing and adjustment must only be performed by Genelec certified service personnel The enclosure must not be opened Do not use this product with a mains cable or mains outlet having no protective earth potential equalizing connection as doing so may result in personal injury To prevent fire or elect...

Page 7: ......

Page 8: ...contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genele...

Reviews: