background image

Genelec 9301A Multichannel AES/EBU Interface

Introduction

Congratulations and thank you for 
purchasing the Genelec 9301A multichannel 
AES/EBU interface intended for 7300 series 
subwoofers. This manual addresses the 
setting up and use of the Genelec 9301A. 

The low frequencies in multichannel digital 

audio AES/EBU signals can be monitored 
by using the 9301A connected to one or 
more 7300 series smart active monitoring 
(SAM) subwoofers, for example products 
7360A and 7370A. These products have 
one built-in AES/EBU input and one output, 
enabling direct monitoring of two digital 
audio channels. The 9301A multichannel 
AES/EBU interface expands the digital audio 
connectivity to 8 audio channels or to 7.1 
channels when the low frequency effects 
(LFE) channel is also used. 

The 9301A unit connects to a subwoofer 

with a simple one-cable link. This cable is an 
AES/EBU cable and carries the sum of all the 
main channel inputs and the LFE channel (if 
used) as the two AES/EBU subframes. 

The AES/EBU output on the 7300-series 

subwoofer connector panel allows easy daisy-
chaining using a single cable onwards to 
multiple subwoofers to enhance and increase 
the subwoofer acoustic output capacity. 

The GLM (Genelec Loudspeaker Manager) 

software manages the 9301A and sets the 
correct settings to enable communication 
between the 9301A and a 7300 series 
subwoofer.  

Each 9301A is supplied with a mains 

cable, one 5 m GLM network cable and an 
operating manual. Before connecting up, 

ensure that the mains power is switched off.

The energy saving Intelligent Signal 

Sensing (ISS) function can be turned on in 
the 9301A to put it automatically into a power 
save state when no AES/EBU input signal is 
present. In the power save state the 9301A 
consumes less than one watt of power. 
Upon sensing an AES/EBU input signal the 

Figure 1. Front and rear panel layouts of the 9301A

AES IN 1

AES OUT 1

AES IN 2

AES OUT 2

SERIAL NUMBER

MAINS INPUT
50 / 60 Hz
12 W 100-240 V~

AES IN 3

AES OUT 3

AES IN 4

(LFE)

AES OUT 4

SUBWOOFER

LINK

GLM NETWORK

THIS DEVICE
COMPLIES WITH FCC
PART 15 AND
CANADIAN ICES-003
RADIO FREQUENCY
CLASS B EMISSION
REQUIREMENTS.
REFER TO
OPERATING MANUAL
FOR FULL
INFORMATION.

RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS EXPOSER À L'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À L'INTÉRIEUR REMPLAÇABLE PAR L'UTILISATEUR. ADRESSER TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ. CET APPAREIL
DOIT ÊTRE RACCORDÉ À LA TERRE.

LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN.

APPARATET MÅ TILKOPLES JORDET STIKKONTAKT. APPARATEN SKALL ANSLUTAS TILL JORDAT UTTAG.

www.genelec.com

WARNING

ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT SUBJECT
TO WATER OR MOISTURE. NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. USE
EARTHED MAINS CONNECTION ONLY.

MADE IN FINLAND

9301A

MULTICHANNEL AES/EBU INTERFACE

AES/EBU INPUT

CONNECTORS

AES/EBU OUTPUT

CONNECTORS

SUBWOOFER LINK

CONNECTOR

GLM NETWORK CONNECTORS

MAINS INPUT CONNECTOR

IN 1

IN 2

IN 3

IN 4

INPUT SIGNAL

INDICATOR LIGHTS

POWER SWITCH WITH INDICATOR LIGHT

Summary of Contents for 9301A

Page 1: ...Genelec 9301A Multichannel AES EBU Interface Operating Manual 9301A ...

Page 2: ...LM network cable and an operating manual Before connecting up ensure that the mains power is switched off The energy saving Intelligent Signal Sensing ISS function can be turned on in the 9301A to put it automatically into a power save state when no AES EBU input signal is present In the power save state the 9301A consumes less than one watt of power Upon sensing an AES EBU input signal the Figure...

Page 3: ...AL IN AES IN 2 AES IN 3 AES IN 4 LFE 7 1 CHANNEL AUDIO SOURCE AES OUT 1 AES OUT 2 AES OUT 3 AES OUT 4 SUBWOOFER LINK AES EBU DIGITAL CABLING GLM NETWORK CABLING POSSIBLE DAISY CHAINED ADDITIONAL SUBWOOFERS AES IN 1 AES IN 2 AES IN 3 AES IN 4 LFE 7 1 4 CHANNEL AUDIO SOURCE GLM ADAPTER AES IN 1 AES IN 2 AES IN 3 AES IN 4 LFE AES EBU DIGITAL CABLING GLM NETWORK CABLING 7 1 4 Figure 3 Audio and GLM ne...

Page 4: ...he mains input supports a wide mains voltage range 100 240 VAC 50 60 Hz and enables the 9301A to be plugged in anywhere globally If the mains power is provided with a generator inverter or certain lower quality UPS devices we recommend filtering of the mains power voltage harmonics and taking care that the voltage supply is stable Controls And Adjustments On the outside of the unit there are a pow...

Page 5: ...d green Power on normal state and operation Blinking green GLM is adjusting the 9301A Green blink every 10 seconds The 9301A is in ISS power saving state No light Power off Input signal indicator light Solid green Valid AES EBU signal detected receiving No light No input detected Table 1 Front panel indicator light functions SPECIFICATIONS Weight 2 kg 4 4 lbs Dimensions Height Width Depth 44 mm 1 ...

Page 6: ...fety standards To ensure safe operation the following warnings and precautions must be observed Servicing and adjustment must only be performed by Genelec certified service personnel The enclosure must not be opened Do not use this product with a mains cable or mains outlet having no protective earth potential equalizing connection as doing so may result in personal injury To prevent fire or elect...

Page 7: ......

Page 8: ...contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genele...

Reviews: