background image

9301A controls are embedded into the 
subwoofer controls.

Use With GLM™ 

Management Network

The 9301A is fully compatible with Genelec 
Loudspeaker Manager GLM™ software 
and the proprietary Genelec monitor 
management network and Genelec SAM 
monitors. More information about the use 
with the GLM™ network is available in the 
SAM System Operating Manual.

System setup 

The setup is easy and consists of the 
following steps:

•  Connect the digital audio to the input 
connectors. If you are using the LFE signal, 
connect the cable carrying the LFE to AES/
EBU 4 connector. Continue with cables 
from the respective outputs to the monitors. 
Use cables intended for carrying AES/EBU 
digital audio. Genelec discourages the use 
of standard analogue microphone cables as 
this may reduce system performance. 
•  Connect the SUBWOOFER LINK output 
to a subwoofer’s DIGITAL IN connector. This 
creates a link for the subwoofer to input a 
sum of all input signals.
•  Connect CAT5 (RJ45) cables between the 
9301A and every monitor and subwoofer. 
Finally connect to the management network 
input of a GLM Adapter device (see Figure 2 
and 3). Notice that the order of connecting 
devices is not significant. 
•  Connect the GLM Adapter device to 
computer USB connector. 

You will find all your devices initially in the 

product stack of the GLM software. When 
you find the 9301A in the product stack, 
drag and drop it to an area on the Layout 
grid adjacent to where the subwoofer will be 
placed (see Figure 5).

In case you have multiple 9301A units, 

observe that when you click with the mouse 
on a 9301A icon, the front panel light on this 
9301A starts flashing, indicating the 9301A 
that is selected in the GLM software. This 
can help in identification. 

When "Input Signal Type" of the Group 

is changed to AES/EBU Digital, all 9301As 
are automatically activated to be part of 
the  group.  At  the  same  time  the  "AES/
EBU Digital Input Mode" of all 7300 series 
subwoofers are turned to Multichannel 

Indicator, colour

Colour, indication

Indication

Power switch

Solid green

Power on, normal state and 
operation

Blinking green

GLM is adjusting the 9301A

Green blink every 10 seconds

The 9301A is in ISS power 
saving state

No light

Power off

Input signal indicator light

Solid green

Valid AES/EBU signal 
detected, receiving

No light

No input detected

Table 1. Front panel indicator light functions

SPECIFICATIONS

Weight

2 kg (4.4 lbs)

Dimensions:

Height 

Width 

Depth

 

44 mm (1 11/16 in) 

466 mm (18 3/8 in) 

211 mm (8 5/16 in)

Mains voltage

100...240 VAC (50...60 Hz)

Mains tolerance

+/- 10 %

Power consumption

ISS power saving mode 

Idle

Full operation

 

1 W 

1 W 

2 W

Digital audio input connectors

4 XLR female

Digital audio input impedance

110 Ohm

Digital audio output connectors

5 XLR male

Digital audio format

AES/EBU (AES3-2003) 

Can also be used with S/P-DIF and AES3id 

signals when impedance converters are 

used

Digital audio word length

Minimum 16 bits, maximum 24 bits. 

Fixed point, AES/EBU format

Digital audio sample rate

Minimum 32 kHz, maximum 192 kHz.

Supports single-wire AES/EBU audio, 

does not support dual wire AES/EBU audio

mode to ensure that multichannel signal is 
reproduced correctly by subwoofers. If all 
9301A devices are set as Group Off then the 
"AES/EBU Digital Input Mode" of all 7300 
series subwoofers is automatically switched 
to Stereo mode to play normal AES/EBU 
digital stereo content. 

When the LFE channel is used, select 

the subframe A or B carrying the LFE audio 
channel. Also, select the “+10 dB” setting for 
the LFE input when you want the subwoofer 
to increase the level of the LFE audio channel 
by 10 dB relative to the main channels.  

As a default, all AES/EBU input channels 

are selected in the 9301 Group Define panel. 
If you do not want all inputs to be bass 
managed, turn off the inputs you want to 
exclude. This can be done by removing the 
respective tick marks under "AES/EBU Digital 
Channels on the SUBWOOFER LINK" section 
of the GLM (see figure 5). Note that one AES/
EBU cable carries two digital audio channels. 

To acoustically calibrate your setup, place 

the Genelec measurement microphone on 
a microphone stand. Put the microphone 
at the listening location pointing upwards 
and its top at ear height. Then follow the 
instructions in the GLM software to measure 

Summary of Contents for 9301A

Page 1: ...Genelec 9301A Multichannel AES EBU Interface Operating Manual 9301A ...

Page 2: ...LM network cable and an operating manual Before connecting up ensure that the mains power is switched off The energy saving Intelligent Signal Sensing ISS function can be turned on in the 9301A to put it automatically into a power save state when no AES EBU input signal is present In the power save state the 9301A consumes less than one watt of power Upon sensing an AES EBU input signal the Figure...

Page 3: ...AL IN AES IN 2 AES IN 3 AES IN 4 LFE 7 1 CHANNEL AUDIO SOURCE AES OUT 1 AES OUT 2 AES OUT 3 AES OUT 4 SUBWOOFER LINK AES EBU DIGITAL CABLING GLM NETWORK CABLING POSSIBLE DAISY CHAINED ADDITIONAL SUBWOOFERS AES IN 1 AES IN 2 AES IN 3 AES IN 4 LFE 7 1 4 CHANNEL AUDIO SOURCE GLM ADAPTER AES IN 1 AES IN 2 AES IN 3 AES IN 4 LFE AES EBU DIGITAL CABLING GLM NETWORK CABLING 7 1 4 Figure 3 Audio and GLM ne...

Page 4: ...he mains input supports a wide mains voltage range 100 240 VAC 50 60 Hz and enables the 9301A to be plugged in anywhere globally If the mains power is provided with a generator inverter or certain lower quality UPS devices we recommend filtering of the mains power voltage harmonics and taking care that the voltage supply is stable Controls And Adjustments On the outside of the unit there are a pow...

Page 5: ...d green Power on normal state and operation Blinking green GLM is adjusting the 9301A Green blink every 10 seconds The 9301A is in ISS power saving state No light Power off Input signal indicator light Solid green Valid AES EBU signal detected receiving No light No input detected Table 1 Front panel indicator light functions SPECIFICATIONS Weight 2 kg 4 4 lbs Dimensions Height Width Depth 44 mm 1 ...

Page 6: ...fety standards To ensure safe operation the following warnings and precautions must be observed Servicing and adjustment must only be performed by Genelec certified service personnel The enclosure must not be opened Do not use this product with a mains cable or mains outlet having no protective earth potential equalizing connection as doing so may result in personal injury To prevent fire or elect...

Page 7: ......

Page 8: ...contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genele...

Reviews: