background image

1030A Operating Manual

Genelec Document D1030AR001 Copyright Genelec Oy 3.2003. All data subject to change without prior notice

www.genelec.com

AMPLIFIER SECTION

CROSSOVER SECTION

SYSTEM SPECIFICATIONS

Lower cut-off frequency, -3 dB:

< 52 Hz

Upper cut-off frequency, -3 dB:

> 20 kHz

Free field frequency response of system:

55 Hz - 18 kHz (± 2.5 dB)

Maximum short term sine wave acoustic output on 
axis in half space, av er aged from 100 Hz to 3 kHz:

@ 1m  > 105 dB SPL
@ 0.5m > 111 dB SPL

Maximum long term RMS acoustic output in same 
conditions with IEC weighted noise (limited by 
driver unit pro tec tion cir cuit):

@ 1m

> 99 dB SPL

@ 0.5m > 105 dB SPL

Maximum peak acoustic output per pair above 
console top, @ 1 m from the engineer with music 
ma te ri al: 

 

 

> 115 dB

Self generated noise level in free field @ 1m 
on axis:

< 10 dB (A-weighted)

Harmonic distortion at 90 dB SPL @ 1m on axis:

Freq:

60...150 Hz

< 3%

 

 

> 150 Hz

< 0.5%

Drivers:

Bass 170 mm (6 1/2") cone
Treble 19 mm (3/4") metal dome

Both drivers are magnetically shielded.

Weight:

7,6 kg (17 lb)

Dimensions:

Height

312 mm (12 1/4")

Width   200 mm ( 7 7/8")
Depth   240 mm (9 7/16")

Bass amplifier short term output power with a 
4 Ohm load: 
 

 

 

80 W

Treble amplifier short term output power with an 
8 Ohm load:
 

 

 

50 W

Long term output power is limited by driver unit 
protection circuitry.

Amplifier system distortion at
nominal out put:
 

 

THD

< 0.08%

 

 

SMPTE-IM

< 0.08%

 

 

CCIF-IM

< 0.08%

 

 

DIM 100

< 0.08%

Signal to Noise ratio, referred to full out put:
 

 

Bass

> 95 dB

 

 

Treble

> 95 dB

Mains voltage:

230, 100/200 or 115/230V 

 

 

according to region

Voltage operating range:

±10%

Power consumption:
 

 

Idle

10 VA

 

 

Full output

100 VA

Input connector XLR female: 
 

 

 

pin 1 gnd

 

 

 

pin 2 +

 

 

 

pin 3  -

Input impedance:

10 kOhm bal anced

Input level for 100 dB SPL output @ 1m:
 

 

variable from +6 to -6 dBu

Input level for maximum short term sine wave output 
of 105 dB SPL @ 1m:
 

 

variable from +11 to -1 dBu

Subsonic filter below 50 Hz :

18 dB/octave

Ultrasonic filter above 25 kHz:

12 dB/octave

Crossover frequency, Bass/Treble:

3.5 kHz

Crossover acoustical slopes:
 

 

24 - 32 dB/octave

Treble tilt control operating range in 2 dB steps: 
 

 

from +2 to -4 dB & MUTE

Bass roll-off control operating range in 2 dB steps:
 

 

from 0 to -8 dB  @ 50 Hz

Bass tilt control operating range in 2 dB steps: 
 

 

from 0 to -6 dB  @ 100 Hz 

 

 

& MUTE

The 'CAL' position is with all tone con trols set to 'off' 
and the input sensitivity con trol to maximum (fully 
clockwise).

International enquiries: 
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]

In the U.S. please contact: 
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]

In China please contact: 
Genelec China Representative Office
Soho New Town, 88 Jianguo Road
D-1504, Chaoyang District
Beijing 100022, China
Phone +86 10 8580 2180
Fax +86 10 8580 2181

Figure 4. The upper curve group shows the horizontal directivity 
characteristics of the 1030A in vertical configuration measured at 1 m. 
The lower curve is a 1/3 octave band power response, measured in an 
IEC approved reverberation chamber.

Figure 5. The curves show the effect of the bass tilt, treble tilt and 
bass roll-off controls on the free field response. 

AUDIO PRECISION 1030anec

vs

14 JAN 94 12:34:40

55

60

65

70

75

80

85

90

90

95

95

100

100

LEVEL(dBr)

20

100

1k

10k

20k

FREQ(Hz)

0
15

30
45

AUDIO PRECISION 1030anec

vs

14 JAN 94 12:09:56

50

55

60

65

70

75

80

85

90

95

100

LEVEL(dBr)

20

100

1k

10k

20k

FREQ(Hz)

TREBLE TILT

BASS ROLL-OFF

BASS TILT

Reviews: