background image

gives  an  SPL  of  100 dB  @1m  with  -6  dBu 
input level. 

Setting tone controls

The response of the system may also have 
to  be  adjusted  to  match  the  acoustic  envi-
ronment. The adjustment is done by setting 
the three tone control switch groups ‘treble 
tilt’, ‘bass tilt’ and ‘bass roll-off’ on the rear 
panel  of  the  amplifier.  The  factory  settings 
for these controls are ‘All Off’ to give a flat 
anechoic  response.  See  Table  1  for  sug-
gested tone control settings. Figure 5 shows 
the  effect  of  the  controls  on  the  anechoic 
response. Always start adjustment by setting 
all switches to ‘OFF’ position. Then set only 
one switch to the ’ON’ position to select the 
response  curve  needed.  If  more  than  one 
switch is set to ‘ON’ (within one switch group) 
the attenuation value is not accurate.

Vertical / horizontal mounting

The  speakers  are  normally  delivered  set 
up for vertical mounting. Horizontal mount-
ing should be avoided due to the increased 
likelihood  of  early  reflections  that  degrade 
the the direct sound. If horizontal mounting 
is needed the DCW plate may be rotated so 
that the Genelec logo remains horizontal by 
removing the four corner screws of the DCW 
and carefully lifting and turning the DCW.

Console top mounting

If the 1030A’s are used for near field monitor-
ing, avoid mounting them on the meter bridge 
of the console. Instead position the speakers 
slightly  behind  the  console  by  using  floor 
stands  or  wall  mounts.  This  prevents  the 
first reflections from the console surface from 
coloring the sound.

Maintenance

No  user  serviceable  parts  are  to  be  found 
within  the  amplifier  unit.  Any  maintenance 
or  repair  of  the  1030A  unit  should  only  be 
undertaken by qualified service personnel. 

Safety considerations

Although  the  1030A  has  been  designed 
in  accordance  with  international  safety 
standards, to ensure safe operation and to 
maintain the instrument under safe operating 
conditions, the following warnings and cau-
tions must be observed:

1.  Servicing  and  adjustment  must  only

be  performed  by  qualified  service 
personnel. The amplifier’s rear panel must
not be opened.

2.  Do  not  use  this  product  with  an

unearthed mains cable as this may lead to
personal injury.

3.  To prevent fire or electric shock, do not

expose the unit to water or moisture. Do
not  place  any  objects  filled  with  liquid,
such as vases on the speaker or near it. 

4.  Note  that  the  amplifier  is  not 

completely  disconnected  from  the  AC 
mains  service  unless  the  mains  power
cord is removed from the amplifier or the
mains outlet.

WARNING! 
This  equipment  is  capable  of  producing 
sound  pressure  levels  in  excess  of  85 dB, 
which  may  cause  permanent  hearing 
damage.

Accessories

 

 

Order code

Protective grille

1030-409

Wall mount

1030-404-V/H*

Floor stand

1030-405-V/H*

*State  the  desired  speaker  orientation 
V=vertical  or  H=horizontal  when  ordering 
these accessories.

Guarantee

This product is supplied with one year guar-
antee against manufacturing faults or defects 
that might alter the performance of the 1030A 
unit. Refer to supplier for full sales and guar-
antee terms.

Figure 1. Amplifier panel layout of the 1030A

Figure 2. Location of the acoustic axis

Speaker Mounting 

Position

Treble tilt

Bass tilt

Bass roll-off

Flat anechoic response

None

None

None

Free standing in a 

damped room

None

-2 dB

None

Free standing in a 

reverberant room

None

-4 dB

-2 dB

Near field or console 

bridge

None

-4 dB

-4 dB

Table 1. Suggested tone control settings in some typical situations

Figure 3. RCA to XLR cable

Cable

Screen

RCA

(Source)

XLR

(Speaker)

Reviews: