6. Close the amber lid above the gel.

7. Now the fluorescent samples can be viewed or cut.

8. When finishing, turning the transilluminator off.

9. Clean the transilluminator filter and surface by wiping with a wet, not scratching cloth.

Troubleshooting

This table below lists the most common problems which you may encounter during using 

the 

μ

BLooK

TM

 LED transilluminator

Related Ordering Information

Note: Please, read the installation instruction carefully before installing the 

μ

BLooK

TM

 LED transilluminator.

This instrument is intended for clinical and research laboratory use and it must be operated 

only by specialized personnel aware of the potential risks associated with the chemical and 

biological agents normally used with this unit. This instrument is meant for use only by 

specialized personnel that know the health risks associated with blue light radiation and with 

reagents that are normally used with this instrument. It is designed to shield only the person 

working in front of the system and to observe the gel fluorescence emission clearly.

       

Maintenance and Repair

Cleaning and Maintenance

The transilluminator should be damply wiped off with a soft cotton cloth. The cloth should not 

be too wet. Do not use aggressive cleaning detergents or solvents.

After use of the transilluminator, we recommend to wipe off the frame and the filter glass with 

a damp cloth. Take care that the cloth is not soaked with scrubbing or corrosive detergents 

as this could damage the filter glass. We suggest using alcohol, glass cleaners or similar 

mild detergents.

Pay attention to wearing appropriate gloves when cleaning areas (as the filter plate of the 

transilluminator, switches, protection shield) which may have been in contact with carcino-

genic or toxic reagents. The protection shield is made of tempered glass and must only be 

cleaned with a damp cloth.

Problem

Low sensitivity

          

High background, 

suboptimal, or no image

Cause

Wavelength may not 

be right

          
Low sample 

concentration

Solution

Check the excitation and 

emission wavelengths of 

the fluorescence dye
Check the concentration 

of sample

Cat. No.

SL001-1000
SL002-0500
SM203-0100
SM205-0100
SM206-0100
SM207-0100

Description

Novel Juice
Novel Green
OnePCR

TM

OnePCR

TM

 HiFi

OnePCR

TM

 HotStar

OnePCR

TM

 

Plus

Size

1 ml

500 μl

100 Reactions
100 Reactions
100 Reactions
100 Reactions

Summary of Contents for uBLOOK BK003-000W

Page 1: ...LED Transilluminator Portal to Life Discoveries ...

Page 2: ...red into position once your gel is mounted The stained gel is now ready for observation μBLooKTM is designed to inspect the gel stained with the Novel Juice Novel Green Novel Green Plus after electrophoresis Further it is perfectly designed for OnePCRTM OnePCRTM HiFi OnePCRTM HotStar which contains the fluorescent stain compatible with the blue light wavelength However μBLooKTM is not suitable for...

Page 3: ...6 mm x 33 mm 88 mm x 119 mm x 10 mm 86 mm x 114 mm x 10 mm 500 g 100 240 V 50 60 Hz 12 V 1 5 A 18 W Built in blue light LED module 30000 hours 470 nm 25 C Ambient to 40 C Amber filter ideal for Novel Juice Novel Green Novel Green Plus OnePCRTM OnePCRTM HiFi OnePCRTM Hotstar OnePCRTM Plus OneMark B OneMark 100 Specifications Contents A Power Cord Used to connect the μBLookTM port with the power soc...

Page 4: ...ton Manual switch button is used for switching on and off the power when press the button P 03 Operating 1 Place the μBLooKTM LED transilluminator on a level bench with enough space around the unit for allowing air circulation and preventing overheating 2 Switch down the rotating bracket connect the power cord and the socket 3 Open the lid of the μBLooKTM LED transilluminator Note The maximum expa...

Page 5: ...enance and Repair Cleaning and Maintenance The transilluminator should be damply wiped off with a soft cotton cloth The cloth should not be too wet Do not use aggressive cleaning detergents or solvents After use of the transilluminator we recommend to wipe off the frame and the filter glass with a damp cloth Take care that the cloth is not soaked with scrubbing or corrosive detergents as this coul...

Page 6: ...d not be modified or altered in any way Alteration of this instrument will 1 Void the manufacturer s warranty 2 Void the safety and EMC certification 3 Create a potential safety hazard GeneDireX Inc is not responsible for any injury or damage caused by the use of this instrument for purposes other than those for which it is intended or by modifications of the instrument not performed by GeneDireX ...

Page 7: ...und the purchase price of this product at no charge to you provided it is returned during the warranty period This warranty does not apply if the product has been damaged by accident abuse misuse or misapplication or from ordinary wear and tear This warranty shall be limited to the replacement of defective products It is expressly agreed that this warranty will be in lieu of all warranties of fitn...

Reviews: