Genebre Building. Av. de Joan Carles I, 46-48
08908 L'Hospitalet de Llobregat. Barcelona (Spain)
[email protected] - www.genebre.es
GENEBRE S.A.
LAST UPDATE: 16/07/2020 UPDATE NUMBER: 0
5
3.4 Adjustment of the regulation screws
The unit is already adjusted in the factory at 0º and 90º, however it could be necessary a
later adjustment in Open and/or Close position of the valve. The range of adjustment is +/-
10º for both positions.
The procedure simply consists on checking that the valve is fully open in Open position and
fully closed in Close position. Adjust the Regulating Screws (part.2) as much as necessary
(between the range of adjustment).
4. Operation instructions
4.1 Manual operation
Manual gearbox designed to be able to manually operate the valve with pneumatic rotary
actuator in case of failure of air or energy.
The gear boxes are manually operated by handwheel. Turn clockwise for closing or turn
counterclockwise for opening the valve.
Do not attempt to force the handwheel beyond the stop limits.
4.2 From Manual to Automatic
1-Pull upwards the lock device (part.9) and turn the handle (part.10) downwards.
2-Let the lock device (part.9) down and move the handle (part.10) to position it.
Opening Screw
Closing Screw