Genebre 5971 Installation, Operation And Maintenance Manual Download Page 4

 

 

 

 
Genebre Building. Av. de Joan Carles I, 46-48 
08908 L'Hospitalet de Llobregat. Barcelona (Spain) 
[email protected]   - www.genebre.es 

 

 

GENEBRE S.A. 

            LAST UPDATE: 16/07/2020                      UPDATE NUMBER:  0 

2. Storage 

 
During storage it is recommended to keep the Gear Operator in the same position as 
delivered, with the included protective wrapping to avoid damages or dirt accumulation. The 
wrap must not be removed until the operator is to be installed. As far as possible, store in a 
dry and clean environment. If you expect to have the product stored for a long period of time, 
apply anti rust oil over machined areas. Repeat every 6 months if necessary.   

 
 

3. Installation instructions 

 

3.1 Preparation 

 
Remove any wrapping material from the product. 
The Gear Operator is delivered in the closed position. 

 
 

3.2 Assembling to the valve 

 

1- Check if the bolt circle on top flange and stem dimensions of the valve coincide with the 
bolt circle and square hole of the gear operator, respectively (connection according to ISO 
5211 standard). 
 
2- Make sure that both valve and gear operator are in fully closed position. 
 
3- Mount the gear box with its shaft perpendicular to the valve (or pipeline) by means of the 
attached four screws and washers. Apply "cross method" for tightening. 
 
 
 

3.3 Assembling to the actuator 

 
1- Check if the holes and pinion dimensions of the actuator coincide with the holes and 
square of the gear operator, respectively (connection according to ISO 5211 standard). 
 
2- Make sure that both actuator and gear operator are in fully closed position. 
 
3- Mount the actuator with its shaft parallel to the pipeline) by means of the four screws and 
washers. Apply "cross method" for tightening. 
 
 
 
 
 
 

Summary of Contents for 5971

Page 1: ...08908 L Hospitalet de Llobregat Barcelona Spain genebre genebre es www genebre es GENEBRE S A LAST UPDATE 16 07 2020 UPDATE NUMBER 0 1 INSTALLATION OPERATION AND MAINTENANCE MANUAL Declutchable Gear...

Page 2: ...ctions 1 Assembly Drawing 3 1 1 Parts List 3 2 Storage 4 3 Installation instructions 4 3 1 Preparation 4 3 2 Assembly to the valve 4 3 3 Assembly to the actuator 4 3 4 Adjustment of the regulation scr...

Page 3: ...NUMBER 0 3 1 Assembly drawing 1 1 Parts list N Name Material Surface Treatment 1 Body WCB Epoxy coating 2 Adjust bolts AISI 304 3 Gear Carbon Steel 4 Top cap WCB Epoxy coating 5 Cap Carbon Steel Pain...

Page 4: ...ar Operator is delivered in the closed position 3 2 Assembling to the valve 1 Check if the bolt circle on top flange and stem dimensions of the valve coincide with the bolt circle and square hole of t...

Page 5: ...on and fully closed in Close position Adjust the Regulating Screws part 2 as much as necessary between the range of adjustment 4 Operation instructions 4 1 Manual operation Manual gearbox designed to...

Page 6: ...art 9 down and move the handle part 10 to position it Important When Pin is pull upwards if handle is unable to move check by turning the hand wheel slightly If unable to pull Pin upward unscrew the p...

Page 7: ...e acting actuator the torque exerted by the actuator with the springs to close the valve must be taken into account Important To operate the valve and actuator manually there is no air pressure inside...

Page 8: ...threaded ends to check if they are loose or with rust Tighten them if necessary 6 Hygiene and Safety Instructions 6 1 Fluids that go through the valve can be corrosive toxic flammable or pollutant Whe...

Reviews: