1.

 

Warnings and Precaution for Safety 
1.1

 

Warnings and Precaution for Safety   
1.1.1  For  safety  purposes,  please  ensure  to  read  user manual  thoroughly 
before using this device. 
 
1.1.2  In  this  user  manual,  no  calibration  of  the  product,  repair  or 
maintenance  stated.  In  the  event  of  technical  issues,  please  contact  the 
authorized dealer or GenBody Inc. for service. 
 
1.1.3  Do  not  disassemble,  repair  or  modify  the  machine  without  any 
permission. 
 
1.1.4  GenBody  is  not  responsible  for  malfunctions  and  damage  to  the 
product caused by irregular operation that is not mentioned in this manual. 
 

1.2

 

Precautions for Installation the Product 
1.2.1 Do not install in an unsafe place. 
 
1.2.2 Do not install near inflammable objects or contaminated places.   
 
1.2.3 Do not install  in areas where moisture is high or exposed to direct 
sunlight, near heaters or near magnetic objects. 
 
1.2.3 Make sure to use provided AC-DC adapter. 
 
1.2.4 Plug the power cable to the grounded power outlet. Plugging to the 
ungrounded power outlet may cause device failure as well as electric shock. 
 
1.2.5 Install the outlet in an easily accessible location. In event of technical 
issues, please disconnect the plug completely to turn off the power. 
 
1.2.6 Do not drop or shock the product when moving. 
 
1.2.7 Be careful as there is a biological risk of cross-infection. 
 

1.3

 

Precautions before Use 

Summary of Contents for Confiscope g20

Page 1: ...w Unless used for making a software copy for approved use in accordance with the copyright law no information contained in this User Manual may be reproduced in whole or in part without the prior writ...

Page 2: ...GenBody Inc Page 2 28 APPENDIX EXPLANATION OF LABEL SYMBOLS...

Page 3: ...installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installatio...

Page 4: ...ept any interference including interference that may cause undesired operation of the device Cet appareil contient des emetteurs recepteurs exempts de licence qui sont conformes aux RSS exempts de lic...

Page 5: ...Use 1 4 Precautions during Use 1 5 Precautions for Storing and Managing the System after Use 2 Product Introduction 2 1 Intended Use 2 2 Principle of Analysis 2 3 Product Components 2 4 Parts Descript...

Page 6: ...6 1 4 Battery Alarm 6 1 5 Incubation Alarm 6 1 6 Equipment Reset 6 1 7 Sleep Timer 6 2 Device Update 7 Cleaning 8 Trouble Shooting 9 Other Information 9 1 System Specification 9 2 System Characteristi...

Page 7: ...manual 1 2 Precautions for Installation the Product 1 2 1 Do not install in an unsafe place 1 2 2 Do not install near inflammable objects or contaminated places 1 2 3 Do not install in areas where mo...

Page 8: ...e level during analysis 1 4 3 When installing the testing cartridge into the tray make sure the cartridge is fully placed on the surface of the tray 1 4 4 Press the operating button after the tray is...

Page 9: ...uffer solution to be tested into the cartridge open the tray insert it into the instrument and press the start button The instrument is testing during the reaction time and the optical module inside t...

Page 10: ...Power Button h USB ports 2 0 A type use for administrator i Battery charging port micro USB j Forced power off switch 3 Installation and Start 3 1 Powering on the system Press the power button on the...

Page 11: ...elete Settings General Settings Brightness Date Time Key Sound Battery Alarm Incubation Time Equipment Reset Sleep Timer Calibration Setup Device Update 3 2 Powering off the system Press the power but...

Page 12: ...as shown below the information will be read and entered into the machine Products without RFID tags cannot be analyzed Please ensure that the RFID tag is attached to the product to be tested If RFID...

Page 13: ...he RFID Tags screen At the Select Item screen navigate to the item to be inspected by using the upper and lower buttons and select it When the Select Lot screen appears you can replace RFID tags by mo...

Page 14: ...pared samples and reagents are injected into the cartridge and the tray is closed immediately Press the analysis button if analysis does not start even when the tray is closed Do not open the tray unt...

Page 15: ...is is not a valid result If the control band is not illuminated due to contamination damage to the product or sample Invalid status may appear and discard the cartridge and re examine it with a new ca...

Page 16: ...sposal act 5 Data Management Select Data Management from the main menu to view and manage past examination results 5 1 Test Records If you have more than one exam history it is arranged in the latest...

Page 17: ...has selected Data Management USB Backup from the main menu the following screen appears Connect the USB memory to the right side of the machine navigate to the time period for which user want to back...

Page 18: ...ce Once you have selected Data Management delete from the main menu the following screen appears navigate to the time period you want to delete and press the Select button Deleted data cannot be retri...

Page 19: ...Time Key Sound Battery Alarm Incubation Alarm Equipment Reset Sleep Timer Calibration Setup Calibration Setup Device Update Serial Number of device and version check Update 6 1 General Setup User can...

Page 20: ...want to change Press the Up Down button to adjust the current date and time and press the Select button to temporarily save the changes Press and hold the select button to return to the General Setup...

Page 21: ...ttery Alarm By entering to Battery Alarm setting user can adjust the strength of the low battery sounds effect by using the up down buttons Press and hold the Select button to return to the General Se...

Page 22: ...he reset with the kit s RFID tag secured The data cannot restore once the initialization has been made Press and hold the power button for 2 to 3 seconds to turn the unit back on after initializing is...

Page 23: ...roceed the update If you want to update to the latest version download the file from PC and copy the downloaded file to the USB drive and connect the USB to the USB port located on the side of the dev...

Page 24: ...user but calibration is only possible by the manufacturer and service center 8 Trouble shooting Problem Suggested Solution In the event of no power 1 If the battery is completely discharged charge for...

Page 25: ...edded Firmware non OS Support Language English USB Port USB A 2 0 1 Port Micro USB 1 Port RFID Module 13 558Mhz for Reading Lot Information Tested temperature is from 20 to 50 Adaptor In Out Rating In...

Page 26: ...each item Max 20 When 20 lot information data are saved 1st stored information is automatically deleted Capacity of measurement data Max 1000 test When 950 tests are saved backup warning is displayed...

Page 27: ...GenBody Inc Page 27 28 10 3 Product Service GenBody Inc 3 18 Eopseong 2 gil Seobuk gu Cheonan si Chungcheongnam do Republic of Korea TEL 82 41 523 8993 Please contact your dealer for service...

Page 28: ...GenBody Inc Page 28 28...

Reviews: