AC Wiring
Power Connection
The RXC-3080 requires 90 to 250 volts AC power to operate. The unit is supplied with a 3 position barrier
terminal block. The terminal screw size is #6 screw and will accept a forked terminal with a maximum width of
.320”. Terminal #3 is grounded to the backplane. This terminal should be bonded/grounded to earth ground.
AC
Connections:
110 Volt
220 Volt
208 / 240 Volt
G
ro
und
Neutral
L1
H
o
t
G
ro
und
L2
H
o
t
L1
H
o
t
G
ro
und
L2
H
o
t
L1
H
o
t
208 / 240 Volt:
Connect Hot Line 1
to “Line 1”
Connect Hot Line 2 to “Line 2”
Connect Earth Ground wire to “GND”
110 Volt :
Connect Hot wire to “Line 1”
Connect Neutral
wire to “Line 2”
Connect Earth Ground wire to “GND”
220 Volt:
Connect Line 1 to “Line 1”
Connect Line 2 to “Line 2”
Connect Earth Ground wire to “GND”