Gemotech RemoDAQ-8017SC User Manual Download Page 27

RemoDAQ-8017S User’s Manual 

3.6 $AA2 

Name

Configuration Status 

Description

The command requests the return of the configuration 

data from the analog input module at address AA. 

Syntax

$AA2(cr) 

$  delimiter character. 
AA address of reading module(00~FF) 
2  the Configuration Status command. 
(cr) the terminating character, carriage return (0Dh). 

Response

!AATTCCFF(cr) if the command is valid. 
?AA(cr)if an invalid operation was entered. 

Syntax error or communication error may get no response. 

!  command is valid. 
?  command is invalid.

 

AA  address of module(00~FF) 
TT  represents the type code. 
CC    represents the baud rate code. 
FF  data format 

  (Also see the %AANNTTCCFF configuration command) 

Example

 

Command

$012  Response

!01090600 

Read address 01 configuration,return success 

 
 
 

 

26

Summary of Contents for RemoDAQ-8017SC

Page 1: ...V1 1 2009 02 11 RemoDAQ 8017SV SC User s Manual Beijing Gemotech Intelligent Technology Co Ltd ...

Page 2: ...ay be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Beijing Gemotech Intelligent Technology Co Ltd Information provided in this manual is intended to be accurate and reliable However Beijing Gemotech Intelligent Technology Co Ltd assumes no responsibility for its use or for any infringements upon the rights of third parties which ma...

Page 3: ...epresentative or Gemotech s customer service center for technical support if you need additional assistance Please have the following information ready before you call z Product name and serial number z Description of your peripheral attachments z Description of your software operating system version application software etc z A complete description of the problem z The exact wording of any error ...

Page 4: ...tion 8 1 7 Install List 10 2 Initialization Installation 12 2 1 Installation Guideline 12 2 2 Software Installation 12 2 3 Basic configuration and hook up 13 2 4 Baudrate and Checksum 15 3 Command Set 17 3 1 AANNTTCCFF 20 3 2 AA 22 3 3 AAN 23 3 4 AA0 24 3 5 AA1 25 3 6 AA2 26 3 7 AA5VV 27 3 8 AA6 28 3 9 AA3V VVVV 29 3 10 AA4 VV 30 3 11 AAA 31 3 12 AAF 32 3 13 AAM 33 3 14 AAO Data 34 3 15 AAEV 35 3 ...

Page 5: ...vide signal conditioning isolation ranging A D and D A conversion data comparison digital commun ication timer counter wireless communication collection AC and other functions RemoDAQ 8017SV is an 8 channel voltage input module RemoDAQ 8017SC is an 8 channel current input module The common features of AI modules are given as following z 3000VDC Isolated analog input z 24 bits sigma delta ADC to pr...

Page 6: ...rential and 2 single ended Input type mA 8017SC V 8017SV Input range 20mA 20mA 8017SC 5V 5V 8017SV Output Speed in bps Maximum distance RS 485 2 wire 1200 2400 4800 9600 19 2K 38 4K 57 6K 115 2K 4000ft 1200m Accuracy 0 5 or better Zero drift 20µV C Span drift 25ppm C Isolation voltage 3000VDC CMR 50 60Hz 86dB Bandwidth 15 7Hz 5 ...

Page 7: ...anual Conversion rate 6 8 samples sec Input impedance 10MΩ Overvoltage Protection 20VP P Power supply 10 30VDC Power consumption 1 3W Operating Temperature 20 70 C Environment Humidity 5 95 non condensing 1 2 Block Diagram 6 ...

Page 8: ...NIT mode Notice 1 RemoDAQ 8017SC measure current wire connection please refer RemoDAQ 8017 But no external 125Ω resistor 2 Because modular is internal to set signal protective circuit under the condition that does not supply power can affect as normal signal produces so must install and gather signal under ensuring the condition of normal power supply and cut off or stop gathering signal before mo...

Page 9: ...rential and 2 single ended mode 1 5 Jumper Setting Jumper JP1 for select the pin INIT Vin 7 Select 8 diff mode the pin INIT Vin7 is set to Vin7 Select INIT mode the pin INIT Vin7 is set to INIT 1 6 Calibration What do you need to do calibration 1 One 5 1 2 digital multimeter 2 A voltage calibrator or very stable and noise free DC voltage generator 3 A precision resistance decade box or discrete re...

Page 10: ...t signal to module s input For RemoDAQ 8017SC SV connect to channel 0 Calibrate for RemoDAQ 8017SC 1 Setting type to 0D 2 Enable calibration 3 Apply zero calibration voltage 4 Perform AA4 VV command until 0 5 Perform zero calibration command 6 Apply span calibration voltage 7 Perform AA3V VVVV command until 20mA 8 Perform span calibration command 9 Repeat step 2 to step 8 three times Calibrate for...

Page 11: ...until 5V 8 Perform span calibration command 9 Repeat step 2 to step 8 three times 1 7 Install List Baudrate Setting CC Code 03 04 05 06 07 08 09 0A Baudrate 1200 2400 4800 9600 19200 38400 57600 115200 Analog Input Type Setting TT RemoDAQ 8017SC Code 09 Min 5V Max 5V RemoDAQ 8017SV Code 0D Min 20mA Max 20mA Data format setting FF 7 6 5 4 3 2 1 0 1 2 0 3 1 0 60Hz Restrain 1 50Hz Restrain 10 ...

Page 12: ... Complement HEX Format Analog Input Type And Data Format Table Code Input span Data format F S Zero F S Project Unit 5 000 00 000 5 000 FSR 100 000 000 00 100 00 09 5V 5V 2 s Complement HEX 7FFF 0000 8000 Project Unit 20 000 0 0000 20 000 FSR 100 000 000 00 100 00 0D 20mA 20mA 2 s Complement HEX 7FFF 0000 8000 11 ...

Page 13: ...for power lines Vs R Red GND B Black We advice that the following standard colors as indicated on the modules be used for the communication lines DATA Y Yellow DATA G Green 2 2 Software Installation 1 If you have already installed RemoDAQ 8000 Utility then skip other steps 2 Backup your software diskette 3 Insert RemoDAQ 8000 Utility disc into CD ROM 4 Change drive to the path of CD ROM For exampl...

Page 14: ...3 Basic configuration and hook up Before placing a module in an existing network the module should be configured Though all modules are initially configured at the factory it is recommended to check that the baud rate is set correctly Default Factory Settings Baud rate 9600 Bit sec Address 01 hexadecimal Checksum disable The basic hook up for module configuration is shown below Figure 2 2 Layout f...

Page 15: ...also be configured by issuing direct commands from a terminal emulation program within what is part of the RemoDAQ utility software The following example guides you through the setup of an analog input module Assume that RemoDAQ 8017SV still has its default settings baud rate 9600 and address 01h Before the module is reconfigured it is first requested to send its default settings To change the con...

Page 16: ...uld be powered down and powered up to force a reboot and let the changes take effect 2 4 Baudrate and Checksum RemoDAQ modules contain EEPROMs to store configuration information and calibration constants The EEPROM replaces the usual array of switches and ports required to specify baudrate input output range etc All of the RemoDAQ modules can be configured remotely through their communication port...

Page 17: ...perform the following steps Power on all components except the RemoDAQ Module Power the RemoDAQ module on while shorting the INIT and GND terminals Wait at least 7 seconds to let self calibration and ranging take effect Configure the checksum status and or the baud rate Switch the power to the RemoDAQ Module OFF Remove the grounding of the INIT terminal and power the module on Wait at least 7 seco...

Page 18: ...meout aborts the sequence and returns control to the host Changing RemoDAQ s configuration might require the module to perform auto calibration before changes can take effect Especially when changing the range the module has to perform all stages of auto calibration that it also performs when booted When this process is under way the module does not respond to any other commands The command set in...

Page 19: ...l string Every command is terminated by a carriage return cr Calculate Checksum 1 Calculate ASCII sum of all characters of command or response string except the character return cr 2 Mask the sum of string with 0ffh Example Command string 012 cr Sum of string 0 1 2 24h 30h 31h 32h B7h The checksum is B7h and CHK B7 Command string with checksum 012B7 cr Response string 01200600 cr Sum of string 0 1...

Page 20: ...ct for gain errors 3 5 AA2 Configuration status Return the configuration parameters for the module 3 6 AA5VV Enable Disable channels for multiplexing Enable or disable the individual channels 3 7 AA6 Read channel status Get the enable disable status of all channels 3 8 AA3V VVVV Set span coefficient Return correct or error 3 9 AA4 VV Set zero excursion Return correct or error 3 10 AAA Read 8 chann...

Page 21: ...um we should INIT termination land 7 6 5 4 3 2 1 0 Not used Figure 3 1 Data format setting of AI modules Response AA cr if the command was valid AA cr if an invalid operation was entered If the INIT terminal was not grounded when attempting to change baud rate or checksum settings Syntax error or communication error may get no response command is valid 0 60Hz Restrain 1 50Hz Restrain 00 Engineer U...

Page 22: ... an input range 5V baud rate 9600 integration time 50 ms 60 Hz engineering units data format and no checksum checking or generation The response indicates that the command was received Table 3 1 Input Rang Codes Type Code RemoDAQ 8017SC Code 09 Min 5V Max 5V RemoDAQ 8017SV Code 0D Min 20mA Max 20mA Table 3 2 Baudrate Code Code 03 04 05 06 07 08 09 0A Baudrate 1200 2400 4800 9600 19200 38400 57600 ...

Page 23: ... AA address of reading module 00 FF cr is the terminating character carriage return 0Dh Response data cr Syntax error or communication error may get no response delimiter character data AI input value the data is the combination for each channel respectively Example Command 01 Response 4C534C0000000000000 0000000000000 Read analog input value at address 01 return values of 8 channels 22 ...

Page 24: ...tly configured data format Syntax AAN cr delimiter character AA address of reading module 00 FF N channel 0 7 cr is the terminating character carriage return 0Dh Response data cr Syntax error or communication error may get no response delimiter character data AI input value For data formats refer sec 1 7 Example Command 32 Response 02 455 Read address 03 and channel 2 return 02 455 23 ...

Page 25: ...id operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of the module 00 FF In order to successfully calibrate an analog input module s input range a proper calibration input signal should be connected to the analog input module before and during the calibration Example Command 010 Response 01 Span calibration of address 01 re...

Page 26: ...id operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of the module 00 FF In order to successfully calibrate an analog input module s input range a proper calibration input signal should be connected to the analog input module before and during the calibration Example Command 011 Response 01 Zero calibration of address 01 re...

Page 27: ... command cr the terminating character carriage return 0Dh Response AATTCCFF cr if the command is valid AA cr if an invalid operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of module 00 FF TT represents the type code CC represents the baud rate code FF data format Also see the AANNTTCCFF configuration command Example Comman...

Page 28: ...e enable disable channels command VV channel enable disable 00 is all disabled and FF is all enable cr is the terminating character carriage return 0Dh Response AA cr if the command was valid AA cr if an invalid operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of the module 00 FF Example Command 0155A Receive 01 Set addres...

Page 29: ...is the terminating character carriage return 0Dh Response AAVV cr if the command was valid AA cr if an invalid operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of the module 00 FF VV channel enable disable 00 is all disabled and FF is all enable Example Command 016 Receive 01A5 Read address 01 channel status return channel...

Page 30: ...ommand V VVVV coefficient 0 5000 1 0000 cr is the terminating character carriage return 0Dh Response AA cr if the command was valid AA cr if an invalid operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of the module 00 FF Example Command 0130 9999 Response 01 Set address 01 coefficient 0 9999 return success 29 ...

Page 31: ...rsion command excursion direction VV excursion value bit cr is the terminating character carriage return 0Dh Response AA cr if the command is valid AA cr if an invalid operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of response module 00 FF Example Command 0140 02 Response 01 Set address 01 zero excursion value 2 return s...

Page 32: ...and cr is the terminating character carriage return 0Dh Response data1 data8 cr if the command was valid AA cr if an invalid operation was entered Syntax error or communication error may get no response command is valid command is invalid AA address of the module 00 FF Data1 Data8 8 channel analog input data in format 2 s complement HEX Example Command 01A Response 011021031025445E0128 EFEE2389DED...

Page 33: ...erminating character carriage return ODh Response AA data cr if the command is valid AA cr if an invalid command was issued Syntax error or communication error may get no response command is valid command is invalid AA address of response module 00 FF Data is the version code of the module s firmware Example Command 01F Receive 01050101 Read address 01 firmware version return version 050101 Comman...

Page 34: ... the Read Module Name command cr is the terminating character carriage return ODh Response AA data cr if the command is valid AA cr if an invalid command was issued Syntax error or communication error may get no response command is valid command is invalid AA address of response module 00 FF data the name of the module Example Command 01M Receive 018017SC Read address 01 module name return name 80...

Page 35: ...odule max 6 characters cr is the terminating character carriage return ODh Response AA cr if the command is valid AA cr if an invalid command was issued Syntax error or communication error may get no response command is valid command is invalid AA address of response module 00 FF Example Command 01O8017SC Receive 01 Set address 01 module name to 8017SC return success Command 01M Receive 018017SC R...

Page 36: ...if the command is valid AA cr if an invalid command was issued Syntax error or communication error may get no response command is valid command is invalid AA address of response module 00 FF Example Command 010 Receive 01 Perform address 01 span calibration return the command is invalid before enable calibration Command 01E1 Receive 01 Set address 01 to enable calibration return success Command 01...

Reviews: