GemOro UltraTester 3+ Manual Download Page 4

GEM

ORO ULTRATESTER 3+

6

7

or identity of the gemstone being 
tested. The final determination 
of the identity of any gemstone, 
whether genuine or not, should only 
be made by a trained gemologist. 
Neither GemOro nor any of its 
affiliates, dealers, or distributors 
shall be held liable for any loss 
and/or damages associated with 
the use of the UltraTester 3+. No 
warranties exist with respect to the 
UltraTester 3+ or its use other than 
those expressly contained herein. 
All other warranties of any kind 
or character whatsoever, whether 
expressed or implied, including 
warranties of merchantability or 
fitness for a particular purpose, are 
hereby disclaimed and are excluded 
from the warranties hereunder. 
In the event that a claim is made 
with respect to the UltraTester 3+ 
or its use, the maximum liability of 
GemOro, and its affiliates, dealers, 
and distributors shall be the amount 
paid for the UltraTester 3+.

PLEASE READ BEFORE USING THE 
PROVIDED NiMH RECHARGEABLE 
BATTERIES: 

 

Before using the NiMH 

rechargeable batteries that have 
been provided with your tester, the 
batteries should be fully charged 
as indicated by the small round 
LED indicator next to the power 
button glowing green when the 
UltraTester 3+ is plugged in.  While 
the batteries are being charged, 
the tester may be used as desired 
while powered by the AC current.   

CONDITIONS FOR 
IDEAL OPERATION 

1.  The UltraTester 3+ should be used 

in the following environmental 
conditions.  Both the tester and 
the stone being tested must 
be the same temperature. By 
not following these instructions 
you risk compromising the 
accuracy of the test.
a. Temperature: 65°F-80°F 
(18°C-27°C) 
b. Air Relative Humidity: 45%-75%

2. The stone being tested must be 

dry. If the surface of the stone is 
wet or has any type of surface 
moisture it may not test correctly. 

3. The stone being tested must be 

clean. Aside from obvious visible 
dirt that may be present on the 
stone, there may also be hand, 
body oil or other contaminates on 
the stones surface that may not 
be visible and which could impact 
the accuracy of the test. Always 
be certain to clean the stone being 
tested with an ultrasonic or steamer 
or other appropriate means, and 
thoroughly dry it and/or remove 
any cleaning chemicals remaining 
on the stone prior to testing. A 
GemOro STONE TESTING CLOTH 
(shown below) has been provided 
with each UltraTester 3+ and for 
convenience it should be used to 
wipe any hand or body oil from 
the stones surface prior to testing.

Summary of Contents for UltraTester 3+

Page 1: ...SIMULTANEOUS DIAMOND MOISSANITE WHITE SAPPHIRE TESTER WITH NEW ADVANCED PATENTED UV F1 IDENTIFICATION TECHNOLOGY UltraTester 3 ...

Page 2: ...r SEE MANUAL NEED HELP Call GemOro at 800 527 0719 for immediate assistance The GemOro UltraTester 3 is the ultimate tester for diamond fraud protection The UltraTester 3 features exclusive UV F1 TECHNOLOGY and is capable of identifying the widest range of the electrically conductive moissanite material available including the new super low electrically conductive Forever One moissanite OPERATING ...

Page 3: ...est result that indicates moissanite especially on smaller size stones that haven t been cleaned should be suspect cleaned and retested Due to the electrical conductivity properties of some of the chemicals commonly used in the production of lab grown synthetic diamonds when the UltraTester 3 s probe tip touches these stones the metal alert feature or moissanite indication may be set off The GemOr...

Page 4: ...ound LED indicator next to the power button glowing green when the UltraTester 3 is plugged in While the batteries are being charged the tester may be used as desired while powered by the AC current CONDITIONS FOR IDEAL OPERATION 1 The UltraTester 3 should be used in the following environmental conditions Both the tester and the stone being tested must be the same temperature By not following thes...

Page 5: ...s unavailable to recharge the NiMH batteries 4 It is imperative that the probe tip be cleaned regularly or ideally prior to performing a test Please be aware that there may be hand oil or other contaminates that may not be visible on the probe tip which could impact the accuracy of the test To clean the tip take a piece of uncoated white printer or copy paper and place the probe tip of the tester ...

Page 6: ...Magnifier attachment which when clipped onto the tester s tip area allows the user to more easily see and test small diamonds without accidentally touching the setting or prongs Item 0780 11 The tester has an auto off function to preserve the battery life and it will automatically turn itself off after a period of 5 minutes of non use After powering down if you wish to resume using the UltraTester...

Page 7: ...er 3 other than to replace the batteries or the warranty will become void UV EYE HAZARD Avoid looking directly into the UV LED OPERATION 1 NiMH Battery Usage and Alkaline Battery Installation To activate the 3 NiMH rechargeable batteries REMOVE THE BATTERY DISCHARGE INSULATOR TAB F that is extending out of the battery compartment by simply pulling it out To increase the life of the NiMH rechargeab...

Page 8: ...ts DC power mode The tester s built in Intelligent Charging Circuit ICC will automatically identify the type of batteries installed NiMH rechargeable batteries or alkaline batteries If alkaline batteries are installed the circuit will automatically cut off the power supply to the batteries so that the alkaline batteries will not be recharged If NiMH rechargeable batteries are installed the batteri...

Page 9: ...e front end of the tester that serves to protect the probe tip from accidentally being bent or broken J The cap may be easily removed by simply applying a minimal amount of pressure to the sides of the cap as you hold it between your thumb and forefinger Then gently pull it out and off Always replace the cap when the UltraTester 3 is not in use 7 To properly hold the UltraTester 3 it is important ...

Page 10: ...nd test properly While holding the UltraTester 3 in your other hand firmly touch the probe tip to the stone is being tested and that the setting or prongs are not accidentally being touched This LED is a special UV type L that may also be used to identify the fluorescence characteristic found in approximately 30 of all diamonds You may also attach the optional GemOro Test Stone Magnifier Item 0780...

Page 11: ...nient location near where it will be used such as on a desk showcase or repair area Take the testers micro USB power cord and plug it into the rear of the UltraDock 3 while plugging the USB into its AC power cube adapter Plug the adapter into a convenient wall outlet You may now simply place the UltraTester 3 in the charging stations cradle with its on bottom edge facing down and the rear of the U...

Page 12: ...ent premature corrosion or battery leakage which is common with old or spent alkaline batteries after a period of time Be aware that damage to the UltraTester 3 may occur if there is battery leakage and it will void the warranty 4 In the event the UltraTester 3 is not used for an extended period of time the batteries should be removed 5 Routinely clean the probe tip 6 The UltraTester 3 is not user...

Page 13: ...on it or waiting a few seconds until it cools if a retest is required If testing diamonds in a pave setting please note it is easy to accidentally overheat the stones next to the one being tested Therefore it is very important that you test the stones while alternating testing one area of the ring and then another while regularly blowing on the stones to cool them off 3 The UltraTester 3 has been ...

Page 14: ...erial number tracking system as interpreted by the factory In the event the UltraTester 3 is no longer available or has been discontinued and warranty coverage is applicable at the factory s sole discretion an equivalent tester may be substituted for the defective UltraTester 3 The purchaser shall incur the cost for postage insurance and handling for all warranty and non warranty repairs Warranty ...

Page 15: ...truments 10455 Olympic Drive Dallas Texas 75220 USA 214 351 0380 or 800 527 0719 214 351 1903 or 800 832 9871 FAX gemoroservice sykessler com www gemoroproducts com warrantyregistration www gemoroproducts com 2018 SKS Inc ...