USING / SETTINGS
- 12 -
* These lines are only displayed in OpenTherm
Plus mode. Also, the relevant functions must be
supported by boiler control.
1)
TSP
= Time switch program
81*
Minimum limitation of flow temperature HC 2
(TV2min)
8 ... TV2max
°C
1
8
82*
Maximum limitation of flow temperature HC 2
(TV2max)
TV2min ... TKmax
°C
1
50
83*
Parallel displacement of heating curve HC2
-4.5 ... +4.5
K
0.5
0.0
Domestic hot water
90*
Reduced setpoint of d.h.w. temperature
(TBWR)
8 ... TBWw
°C
1
40
91
Release of d.h.w. heating
24h/day,
TSP
1)
HC -1h,
TSP HC, TSP D.H.W.
-
-
24 h /
day
92*
Legionella function
Off, on
-
-
on
93*
Operating mode of d.h.w. heating
Without Eco,
with Eco
-
-
with
Eco
94*
Control of d.h.w. circulating pump
D.h.w. release
D.h.w. program
Program 2
-
-
D.h.w.
progra
m
General
95
Operation lock
Off, on
-
-
Off
96*
Clock time master
QAA73, external
-
-
QAA73
97
Summer time start
1. jan ... 31 dec
tt.mm
1 day
25
March
98
Summer time end
1. jan ... 31 dec
tt.mm
1 day
25 okt
Line
Function
Range/display
Unit
Resolution
Factory
setting