User guide – Plotter Flexipen 120/165
Plan
6
-
Place the main frame of the machine on the up side of the pillars and fix it with
bolts.
-
The recovering and the feeding paper reels spindle will be mounted with one side
on the engine couple and with one side on the stand supports.
-
Plug the sensor jack from the girder of lower bracket and the engine jack on the
connecting machines frame, than plug the power jack of the machines frame to the
plotter. The label from the plug jack must match to the label from the socket jack.
-
Make sure the plotter is leveled using a level measuring instrument. If the plotter is
not leveled adjust it by screwing up the reels bolts, or by unscrewing them.
-
Plug the serial wire jack in the plotter jack and fix it using bolts;
-
The other serial wire jack will be plugged in the computer port and it will be fixed
with bolts.
Chapter 3:
Plotter charging
-
The power cable must be plugged in a socket which has reliable ground conductor.
-
The power in the cable must not vary more than 5%;
-
To prevent power variation use a UPS source of minimum 500w.
-
Be sure that the On/Off button is in the off position before you plug in the charging
cable.
-
Turn on the plotter. The display will be activated and you will be able to see the
following message: “Welcome to use CAD Plotter”, in the mean time the pen will
go in the park position on the right side of the plotter. After about 5 seconds the
plotter status message “LEAVE”, the writing speed and the pen pressure will be
displayed.
If you turn off the plotter from the back side button, before you turn it on again you
will have to wait for about 10 seconds.
Power variations might cause important plotter damages.
We recommend connecting both plotter and computer in the same socket.
As long as the plotter is plugged in, do not connect the serial wire to the computer.
First unplug the plotter and then connect the wire to the computer, and after that you
may turn the plotter back on.