APPENDIX “D” - GEMINI DUAL COUNTER MODE FUNCTION COMMAND CODE SUMMARY
CODE
MODE
DESCRIPTION
COMMENTS
65
CNTR A DECIMAL POINT & LEAD ZERO BLANKING
(+) Leading Zero Blanking Enabled
(-) Leading Zero Blanking Disabled*
+/-1
No Decimal Point
+/-2
Decimal Point Right of Digit 2
+/-3
Decimal Point Right of Digit 3
+/-4
Decimal Point Right of Digit 4
+/-5
Decimal Point Right of Digit 5
+/-6
Decimal Point Right of Digit 6
66
“OPERATOR ACCESSIBLE FUNCTIONS” MODES
“PGM DIS” Terminal connected to “Comm”
(+) Reset Button & “RST” Terminal Enabled
Front panel reset can be independently disabled by using
DIP switch.
(-) Reset Button & “RST” Terminal Disabled*
This mode has no affect on the “RST A” terminal which is
always enabled.
+/-1
No Functions Enabled
+/-2
Preset Programming Enabled
+/-3
Scale Factor Programming Enabled
+/-4
Preset & Scale Factor Programming Enabled
+/-5
Preset & Counter Load Programming Enabled
+/-6
Preset, Scale Factor & Cnter Load Programming Enabled
1
PRESET 1
Up to +/-999999
2
PRESET 2
Up to +/-999999
3
Display A
COUNTER A SCALE FACTOR
Up to +/-5.9999
3
Display B
COUNTER B SCALE FACTOR
Up to +/-5.9999
E &
Display A
COUNTER A COUNTER LOAD VALUE
Up to +/-999999. Counter Load value is NOT saved in
+/-
memory when power is removed.
E &
Display B
COUNTER B COUNTER LOAD VALUE
Up to +/-999999. Counter Load value is NOT saved in
+/-
memory when power is removed.
*
Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]