APPENDIX “D” - GEMINI COUNTER/RATE MODE FUNCTION COMMAND CODE SUMMARY
CODE
MODE
DESCRIPTION
COMMENTS
56
COUNTER RESET MODES (Cont’d)
+/-1
Manual Reset to Zero
Automatically selected when outputs are configured for rate
[51 3] or when boundary mode is used [54 6].
+/-2
Manual Reset to Preset**
+/-3
Automatically Reset to Zero after Timed Output**
+/-4
Automatically Reset to Preset after Timed Output**
+/-5
Automatically Reset to Zero at Preset**
Counter resets as soon as Output is activated.**
+/-6
Automatically Reset to Preset at Zero**
61
RATE RIGHT-HAND DUMMY ZEROS
1
1 Dummy Zero
2
2 Dummy Zeros
3
3 Dummy Zeros
4
No Dummy Zeros
62
RATE CONVERSION FACTOR
1
Rate Per Second (x1)
2
Rate Per Minute (x60)
3
Rate Per Hour (x3600)
63
RATE MINIMUM UPDATE TIME
1
0.5 Sec minimum/1 Sec maximum
2
1 Sec minimum/2 Secs maximum
3
2 Secs minimum/4 Secs maximum
4
4 Secs minimum/8 Secs maximum
5
8 Secs minimum/16 Secs maximum
Maximum rate = 7500 cps
6
16 Secs minimum/32 Secs maximum
Maximum rate = 3250 cps
64
RATE SCALE MULTIPLIER
1
1000
2
100
3
10
4
1
*
Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.
**
For the Gemini 4200, all reset to preset modes reset to preset 2 and Timed Output refers to Output 2.