System configuration with the parameters detailed in par.12.0 is done by pressing buttons “A” and “B” on the buzzer (see figure below).
Press button “A” to select the parameter to configure.
Press button “B” to select the desired setting.
11.1 - HOW TO ENTER IN PROGRAMMING MODE:
1.
Turn ignition “ON”.
2.
Simultaneously press buttons “A” and “B” for approx 4 sec.
3.
Operation will be confirmed by 1 Beep and 1 Red/Green LED flash.
4.
Wait until the LED turns OFF.
11.2 - PARAMETER SETUP:
1.
Within 10 sec. after the LED turns OFF, press button “A” the number of times corresponding to the parameter to customize. At each button press there will be 1
Beep and 1 Red LED blink.
2.
Press button “B” the number of times corresponding to the desired setup. At each button press there will be 1 Beep and 1 Green LED blink.
Example: To set the maximum detection distance of the inner sensors at 80 cm => press button “A” twice and then button “B” 9 times.
11.3 - SETUP CONFIRMATION
:
1.
The buzzer will repeat the number of Beeps and blinks corresponding to the selected setup. After a few seconds, if the code has been successfully programmed, the
buzzer will give off a ‘Jingle’. Proceed with another setup.
2.
In case of an incorrect entry, a low tone signal (Bop) will sound. Re-enter the desired code.
Cycle ignition key OFF and ON and start the engine to transfer the new parameters from the buzzer to the control unit. The LED on the ON/OFF switch will blink during data
transfer (data transfer timeout: 20 sec. max). A ‘Jingle’ will confirm data has been successfully transfered otherwise a Bop will sound. In this case, cycle ignition key OFF and ON
and restart the engine to repeat data transfer. At the next engine start, the system will operate according to the configured parameters.
11.4 - RESTORE FACTORY SETTINGS
1.
Simultaneously press and hold buttons “A” and “B”; turn ignition ON.
2.
When the buzzer gives off a Beep, release buttons “A” and “B”.
3.
The LED will start blinking Red/Green.
4.
When the LED stops blinking, a Jingle” will confirm the buzzer has been reset to the original factory settings.
5.
Cycle ignition key OFF and ON and start the engine to transfer parameters from the buzzer to the control unit. The LED on the ON/OFF switch will blink during data
transfer (data transfer timeout: 20 sec. max). A Beep will confirm data has been successfully transfered otherwise a Bop will sound. In this case, cycle ignition key
OFF and ON and start the engine to repeat data transfer.
11.5 – HOW TO PAIR A NEW UNIT
If a unit is replaced, carry out pairing as follows:
1.
Disconnect the control unit from the battery.
2.
Connect the buzzer.
3.
Turn ignition key ON.
4.
Simultaneously press buttons “A” and “B” for approx 4 sec.
5.
Operation will be confirmed by 1 Beep and 1 Red/Green LED flash.
6.
Wait until the LED turns OFF.
7.
Within 10 sec. after the LED turns OFF, press button “A” 9 times and button “B” 9 times. At each button press there will be 1 Beep, 1 Red LED blink for button “A”
and 1 Green LED blink for button “B”.
8.
The buzzer will repeat the number of Beeps and blinks.
9.
When the buzzer gives off 3 Beeps immediately connect the control unit to the battery.
10.
A “Jingle” will confirm that the 2 devices have been paired (pairing must be carried out within 30 sec.)
11.
To complete the setup, turn ignition key OFF, the devices will be fully operational.
12.
If on the other hand a Bop sounds, you will need to repeat the entire procedure.
Before configuring the system, ensure all connections have been done properly.
Parameters must only be configured by qualified personnel.
11.0 - PARAMETER SET-UP
Button
A
Button
B
LED