12
Series 958 Embedded Linear Displacement Transducer
1080 North Crooks Road, Clawson, MI 48017 • Phone: 248-435-0700
Protection
Polarity
Reverse polarity protected
Overvoltage
Transient overvoltage protection to +33VDC
Output Resolution
0 to 10VDC
16 bits (0.0015% of span)
0 to 5VDC
15 bits (0.0031% of span)
0.25 to +4.75VDC
~15 bits (0.0034% of span)
0.5 to +4.5VDC
~15 bits (0.0034% of span)
4 to 20mA
15.7 bits, calibrated for 3.5-21mA (0 - 21mA, 16 bits)
Output Loading
Voltage
2k
Ω
minimum
Current
500
Ω
maximum
Connection Options
Integral Cable
Multi-conductor, 26 AWG, shielded, PUR jacket (-40º C to +90º C)
5 Pin - M12
A-Code, Shell installed from “outside” cylinder (IEC 61076-2-101)
Wire - Bare Leads
Multi-conductor, 26 AWG
Isolation
Housing to any signal
500V
Approvals
CE (Electromagnetic Compatibility)
2014/30/EU - When installed in grounded metal housing
RoHS 2
2011/65/EU
Electromagnetic compatibility - Part 6-4:
Generic standards –
Emission standards for industrial
environments
EN61000-6-4
Electromagnetic compatibility (EMC) -
Part 6-2: Generic standards –
Immunity for industrial environments
EN61000-6-2
Agricultural and forestry machinery
ISO 14982:1998
Road vehicles - electrical disturbances
from narrowband radiated
electromagnetic energy — Part 5:
Stripline
ISO 11452-5
Road vehicles - Electrical disturbances
from conduction and coupling
ISO 7637-1/2/3
Earthmoving Machinery
ISO 13766
Industrial Trucks
EN 12895
Railway Applications
EN 50121-3-2