The equipment described in this document is not intended to be used in connection with any application 
requiring fail-safe performance, unless the application design includes appropriate redundancy. This 
exclusion includes, but is not limited to, the direct operation of any life support system or any other system 
whose failure could lead to serious injury, death, environmental damage or mass destruction. 

 Copyright 2013 by Gamatronic Electronic Industries Ltd.   All rights reserved worldwide. 

Any representations in this document concerning the performance of Gamatronic's product(s) are for informational purposes only and are not 
warranties of future performance, either express or implied. 

Gamatronic's standard limited Warranty, which accompanies its sales contract 

or order confirmation form, is the only warranty offered by Gamatronic Electronic Industries Ltd. in relation thereto.

 

Gamatronic Electronic Industries Ltd. ("Gamatronic") warrants the products it manufactures to be free from defect for a period of one calendar 
year from the date of invoice, including the date of invoice. Gamatronic's liability is limited to repairing or replacing any defective parts in the 
equipment under warranty. Gamatronic reserves the right to determine whether the repair work shall be performed at Gamatronic's factory, at the 
customer's premises, or at an alternate site. The customer must obtain authorization from Gamatronic before returning any parts or equipment to 
Gamatronic for repair or replacement. Any items returned to Gamatronic must be sent freight prepaid.  

Gamatronic’s liability and warranty to the product are according and subject to the fulfillment and implementation by the customer of all the terms 
and instructions in connection with “preventive maintenance” and “service and repair” as further detailed in the user guide which is attached to 
the product and forms an integral part of it.” 

Gamatronic is not responsible for any damage to the product due to unauthorized repair work, misuse or abuse of the product, or force majeure. 
If the product is delivered without batteries, Gamatronic is not responsible for any damage or malfunction due to incorrect wiring of the batteries.

 

Gamatronic is not liable for and the Purchaser waives any right of action it has or may have against Gamatronic for any consequential or special 
damages arising out of any breach of warranty, and for any damages that the Purchaser may claim for damage to any property or injury or death 
to any person arising out of its purchase or the use, operation or maintenance of the subject product. 

This warranty includes parts and labor; however, Gamatronic shall not be responsible for any labor subcontracted or performed by the Purchaser 
to prepare the warranted item for return to Gamatronic or Gamatronic's agent. 

The information contained in this document is proprietary and is subject to all relevant copyright, patent and other laws protecting intellectual 
property, as well as any specific agreement protecting Gamatronic's rights in the aforesaid information. Neither this document nor the information 
contained herein may be published, reproduced or disclosed to third parties, in whole or in part, without the express, prior, written permission of 
Gamatronic. In addition, any use of this document or the information contained herein for any purposes other than those for which it was 
disclosed is strictly forbidden. 

Gamatronic reserves the right, without prior notice or liability, to make changes in equipment design or specifications. 

Information supplied by Gamatronic is believed to be accurate and reliable. However, no responsibility is assumed by Gamatronic for the use 
thereof nor for the rights of third parties which may be affected in any way by the use thereof. 

This document may contain flaws, omissions or typesetting errors; no warranty is granted nor liability assumed in relation thereto unless 
specifically undertaken in Gamatronic Electronic Industries Ltd. standard limited Warranty. Information contained herein is periodically updated 
and changes will be incorporated into subsequent editions. If you have encountered an error, please notify Gamatronic Electronic Industries Ltd. 
All specifications are subject to change without prior notice. 

 

 
 

 

Summary of Contents for SCE-1000

Page 1: ...7 Hartom St P O B 45029 Jerusalem 91450 Israel Tel 972 2 588 8222 Fax 972 2 582 8875 Email info gamatronic co il Website www gamatronic com SMART COMPACT UPS User s Manual 650 VA 750 VA 1000 VA 1500 VA Release 1 8 November 2013 2MUXSMART E ...

Page 2: ...esponsible for any damage to the product due to unauthorized repair work misuse or abuse of the product or force majeure If the product is delivered without batteries Gamatronic is not responsible for any damage or malfunction due to incorrect wiring of the batteries Gamatronic is not liable for and the Purchaser waives any right of action it has or may have against Gamatronic for any consequentia...

Page 3: ...L OF THE UPS 4 3 1 Audible alarms 5 4 INSTALLATION INSTRUCTIONS 6 4 1 Site preparation 6 4 2 Access to the UPS 6 4 3 Before first use the UPS Battery must be charged 6 4 4 Installing the SMART COMPACT UPS 6 5 OPERATION INSTRUCTIONS 7 5 1 Starting the UPS 7 5 2 Turning off the UPS 7 5 3 Testing the UPS batteries 7 5 4 Installation and use of the monitoring software 8 6 TROUBLESHOOTING 8 7 PREVENTIV...

Page 4: ...iv This page left blank deliberately ...

Page 5: ...o repair it yourself WARNING Appropriate precautions should be taken during inspection and servicing there is a risk of lethal electric shock The battery cabinet contains 12 Volt batteries that provide high voltage even when the UPS is not connected to the mains 1 2 Don ts Do not open the cover under any circumstances Do not insert any objects through the ventilation holes Do not place objects on ...

Page 6: ...T UPS supplies stable backup power to your computer or other connected device from internal batteries There is no interruption of power to your computer The SMART COMPACT UPS informs you of the loss of ac power by lighting the orange LED on the front panel and beeping every four seconds The length of time that the SMART COMPACT UPS can supply backup power depends on the power usage of the attached...

Page 7: ...hen there is no ac mains voltage Automatic self test at startup and immediate notification of low battery and overload conditions Protected against overload and against short circuit in the attached equipment Immediate notification of ac power failure via LED and audible alarm 2 4 Included with your SMART COMPACT UPS Two power cables with male female ends for connecting a computer and a monitor sc...

Page 8: ...Ltd Smart Compact UPS Front and rear panel of the UPS 4 3 FRONT AND REAR PANEL OF THE UPS The UPS features shown in Figures 1 and 2 are explained in Table 1 Figure 1 Front view of the Smart Compact UPS Figure 2 Rear view of the Smart Compact UPS ...

Page 9: ...orts for modem phone line These two female RJ11 ports one for input and one for output enable you to protect a single modem line or telephone line from power surges 8 USB type A port Used to connect the UPS to the computer if it is desired to use the unattended shutdown feature when a power failure occurs 9 Ac output sockets Supply stabilized ac power and uninterrupted power in the event of an ac ...

Page 10: ...into the ac power main 2 Turn on the UPS by pressing the ON OFF button for 6 seconds 3 Leave the UPS in this state for at least 8 hours with no devices connected to it 4 After 8 hours the UPS is ready for use 4 4 Installing the SMART COMPACT UPS To prepare the UPS for first use 1 Verify that the ac power mains voltage is a nominal 230 Vac 2 Connect the UPS ac input to the ac power main For this pu...

Page 11: ...rder to conserve battery power the UPS performs no self test at startup The actual length of time the load device can be operated in this mode depends on the power consumption of the load device and the battery charge level To perform a cold start of the UPS Press the On Off button for 6 seconds 5 2 Turning off the UPS 1 Turn off the computer or other load devices connected to the UPS 2 Press the ...

Page 12: ...ave defined in the shutdown software has elapsed 6 TROUBLESHOOTING The UPS advises you of exceptional condiditions by means of its LEDs and a beeping alarm Table 3 outlines some of the most common problems and their solutions Table 3 Troubleshooting Problem Probable cause Possible solution The UPS does not start up even though the input ac power is OK 1 Input ac cable not properly connected to the...

Page 13: ...rantee period Gamatronic bears no liability for damage caused to the UPS due to improper maintenance by third parties in particular after the expiration of the warrantee or service agreement It is the responsibility of the UPS owner to uphold his responsibilities according to the warrantee or service agreement This includes ensuring that the UPS s environment meets requirements 8 SERVICE AND REPAI...

Page 14: ...put fuse protection UPS output cuts off immediately ALARM Battery back up Beep every 4 s Battery low Beep every 1 s Overload Continuous beep INDICATORS Green LED Power on normal operation Red LED Battery low overload Yellow LED Battery mode GENERAL Standard features Auto sensing of input frequency Cold start function UPS auto restart Green mode inverter auto shutdown when no load Telephone modem p...