BGS2T AT Command Set
17.5 AT^SCTM
BGS2T_ATC_V01.301
Page 513 of 554
1/31/12
c
Unsolicited Result Code
URCs will be automatically sent to the TE when the temperature reaches or exceeds the critical level, or when it
is back to normal.
^SCTM_B:
URC for BGS2T device temperature warning.
Parameter Description
URC presentation mode
0
(&F)(P)
Disable URC presentation (except for
equal to -2 or +2).
1
Enable URC presentation.
-2
Below lowest temperature limit (causes immediate switch-off)
-1
Below low temperature alert limit
0
Normal operating temperature
1
Above upper temperature alert limit
2
Above uppermost temperature limit (causes immediate switch-off)
0
(&F)(P)
Suppress output of
in read command.
1
in read command.
Board temperature in Celsius. Is comprised between the lowest temperature warning level and the uppermost
temperature warning level.
Examples
EXAMPLE 1
URCs issued when the operating temperature is out of range:
EXAMPLE 2
URCs issued when the temperature is back to normal (URC is output once):
17.5.1
Deferred shutdown
In the following cases, automatic shutdown will be deferred if a critical temperature limit is exceeded:
•
while an emergency call is in progress
•
during a two minute guard period after powerup. This guard period has been introduced in order to allow for
the user to make an emergency call. The start of any one of these calls extends the guard period until the end
of the call. Any other network activity may be terminated by shutdown upon expiry of the guard time.
<UrcMode>
(num)
<UrcCause>
(num)
<tempCtrl>
(num)
<temp>
(num)
^SCTM_B: 1
Caution: Module close to overtemperature limit.
^SCTM_B: 2
Alert: Module is above overtemperature limit and switches off.
^SCTM_B: -1
Caution: Module close to undertemperature limit.
^SCTM_B: -2
Alert: Module is below undertemperature limit and switches off.
^SCTM_B: 0
Module back to normal temperature.