c
using the values for PDP type and address provided by the network. The other parameters will be set to their
default values (see
).
If activation is successful, data transfer will proceed.
After data transfer is complete, and the layer 2 protocol termination procedure has completed successfully,
the V.250 command state is reentered and BGS2T returns the final result code OK.
In the event of an erroneous termination or a failure to start up, the V.250 command state is re-entered and
BGS2T returns the final result code NO CARRIER, or if enabled, "+CME ERROR:
". Attach, activate and
other errors may be reported. It is also an error to issue the
command when there is no pending
network request.
The command can be used in both normal and modem compatibility modes.