V 02/22
OptiGun GA03-E
Start-up
•
15
Start-up
Preparation for start-up
Basic conditions
When starting up the OptiGun GA03-E Enamel automatic gun, the follow-
ing general conditions impacting the coating results must be taken into
consideration:
–
Gun correctly connected
–
Gun control unit correctly connected
–
Corresponding power and compressed air supply available
–
Powder preparation and powder quality
Connecting the OptiGun Enamel automatic gun
The OptiGun GA03-E Enamel automatic gun is delivered ready-to-use by
the manufacturer. Just a few cables and hoses must be connected.
The compressed air must be free of oil and water!
The gun is connected as follows:
1.
Connect electrode rinsing air hose and powder hose to gun
2.
Lay out gun cable, electrode rinsing air hose and powder hose and
bind using Velcro strips (included)
3.
Connect the gun cable plug to the socket
2.3
on the rear side of the
control unit
4.
Connect electrode rinsing air hose to coupling
1.4
5.
Connect powder hose to injector
6.
Connect the gun plug to the gun control unit (see therefore the oper-
ating manual of the gun control unit)
7.
Connect the electrode rinsing air hose of the control unit to the gun
8.
Connect the powder hose from the gun to the injector