V
04/17
30
•
Cleaning / color change
OptiCenter OC04
3. Close the booth doors
4. Clean the guns externally
5. Adjust the movement axes to the cleaning position, so that the guns
can be cleaned from the inside.
OptiCenter
6. Open fully the exhaust air with hand lever
7. Empty the powder container:
−
Place the powder packaging (box or similar) under the powder
container
−
Press the hand lever parts together and turn it 90° counterclock-
wise.
The powder in the powder container empties into the packaging.
8. Press
the
push button, in order to switch off the recovery
powder pump
−
the push button lamp goes out
9. Select the powder recovery mode (
with
or
without powder recov-
ery
)
−
Connect the recovery hose manually:
= Coating with powder recovery (spray)
= Coating without powder recovery (spray to waste)
10. Press the
push button, in order to switch on the recovery
powder pump
−
the push button lamp illuminates
11. Press the
push button, in order to clean the powder hoses to
the guns
12. Basic booth cleaning can be started now already: Activate the corre-
sponding command on the Magic Control CM30/22
13. Switch off the powder container fluidization
14. Press the
push button, in order to switch off the recovery
powder pump
15. Use a squeegee to empty the powder container completely
16. Turn the hand lever back, closing the emptying valve and remove the
powder packaging
−
the push button lamp goes out
17. Open fully the powder container aeration with hand lever
18. Continue with fine cleaning of the powder container, OptiCenter and
booth with compressed air