Fault clearance
HFF01
Faults
The following lists possible faults during operation and their clearance.
Fault
Cause
Corrective action
Powder is not
agitated
Defective fuse in
agitator unit
Replace
Control cable not
inserted or incorrect
Insert, use original
cable, check wiring
Emergency STOP
button activated
Reset emergency
STOP button
Free movement of
the agitator unit
impaired
Check the
mechanical
operation of the
agitator unit
Powder is not
fluidized
Compressed air not
available
Connect device to
compressed air
Fluidizing air set too
low
Set fluidizing air
correctly