Rev. 00 03/22
OptiFeed BigBag (FPS16)
Start-up
•
33
Procedure description
If the powder flow measurement of pump 1 or 2 reacts, the analog inputs
of the pump 1 or pump 2 are set. This means, that no powder will be fed
now (pinholing, powder container is empty or hose is bent).
After the time set in
B001
, the signal will be transmitted to
B002
. The
powder container is now lowered and lifted again, according to
B002
parameters.
At the same time,
B014
will be activated (error message delay). After the
elapse of the set duration, the indicator lamp on the control cabinet door
will be activated. At the same time, the potential-free contact is set, which
can be evaluated by an external reporting device.
Adjusting the threshold values
Lower threshold value
The lower threshold depends of the length of the conveying distance and
the filling by the powder pump.
Example:
Length of the feed
section
Default value
Action
15 m
150
OK
5 m
approx. 80
adjust
Upper threshold value
The upper threshold value limits the correct functionality of the powder
transport. The exceeding signifies a malfunction (powder hose is clogged
or bent).
Example:
Default value value
900 corresponds to 2.2 bar
(suction and conveying
procedure of the pump will be limited)
Functional check
1.
Turn on the vibrator switch
2.
Activate the powder transport (manually or by an external,
superordinated control unit)
3.
The fluidizing air and the vibration must be in operation
Summary of Contents for FPS16
Page 6: ......
Page 34: ...Rev 00 03 22 34 Start up OptiFeed BigBag FPS16 ...
Page 38: ...Rev 00 03 22 38 Operation OptiFeed BigBag FPS16 ...
Page 52: ...Rev 00 03 22 52 Fault clearance OptiFeed BigBag FPS16 ...
Page 54: ...Rev 00 03 22 54 Disposal OptiFeed BigBag FPS16 ...
Page 60: ......
Page 62: ...Rev 00 ...